3-11
3.8
Wiring of Regenerative Alarm Contact <CNA>
(For 500W Level Drive Only)
This driver (with regenerative terminal) is equipped with a regenerative circuit failure detection circuit. When
connecting the regenerative circuit, build a sequence circuit as shown in the figure below in order to prevent
burnout incidents.
Note: Build a sequence circuit so that it will turn off the power supply at alarm operation.
<TB1>
MC
<CNA>
L
N
MC
ON
OFF
MC
Regenerative
alarm
250 V AC 0.1 A
30 V DC 1 A
MC
LINE
Driver
<CNA>
Made by Phoenix Contact
(plug: MC1, 5/2-ST-5, 08)
7 mm
Blade point of the driver used
Thickness 0.4mm, width 2.5mm
(clamping torque: 0.22 to 0.25 [N-m]
Direction of
insertion
3