4. Maintenance
3160-A2-GB21-90
February 2001
4-13
Table 4-4.
Enterprise-Specific Trap Definitions
Trap Value
Event
enterpriseClockFail(1)
The currently configured master clock source has failed.
enterpriseSelfTestFail(2)
A DSU/CSU hardware failure is detected at self-test. This
trap is generated after DSU/CSU initialization.
enterpriseDeviceFail(3)
An internal DSU/CSU failure is detected by the operating
software.
enterpriseTestStart(5)
A test is initiated.
enterpriseConfigChange(6)
A configuration option is changed.
enterpriseTestClear(105)
A test is concluded.
Table 4-5.
SNMP Trap per Interface
Interface
Trap Meaning
T1 Network
Up = No alarm or test conditions.
Down = Alarm or test conditions.
DTE Drop/Insert (DSX-1)
Up = No alarm or test conditions, and the interface is
enabled.
Down = Alarm or test conditions, or the interface is
disabled.
Synchronous Data Ports
Up = No test conditions, the port is assigned to a network
interface, and both CTS and DSR are ON.
Down = Test conditions, the port is unassigned, or either
CTS or DSR is off.
Содержание 3160-A3
Страница 16: ...About This Guide x February 2001 3160 A2 GB21 90...
Страница 24: ...1 Introduction 1 8 February 2001 3160 A2 GB21 90...
Страница 100: ...3 Operation 3 66 February 2001 3160 A2 GB21 90...
Страница 142: ...A Front Panel Menu A 2 February 2001 3160 A2 GB21 90...
Страница 198: ...C Configuration Options C 54 February 2001 3160 A2 GB21 90...
Страница 246: ...E SNMP MIB Objects E 32 February 2001 3160 A2 GB21 90...
Страница 280: ...H Asynchronous Terminal Operation H 24 February 2001 3160 A2 GB21 90...
Страница 282: ...I Equipment List I 2 February 2001 3160 A2 GB21 90...