4. Maintenance
4-2
February 2001
3160-A2-GB21-90
3. View the results of the last power-up self-test. If no problems were found
during power-up, the following message appears.
Table 4-1.
Self-Test Health Messages
Message
Description
Passed
No problems were found during power-up.
CPU fail
The central processing unit failed internal testing.
Device fail
One or more of the unit’s integrated circuit chips failed to pass
internal device level testing.
B8ZS/LOS fail
The unit failed to encode data properly or to detect Loss Of
Signal.
Alarm fail
The unit failed to transmit AIS or to detect an Yellow alarm.
Memory fail
The unit failed program checksum verification.
LCD fail
The front panel liquid crystal display (LCD) failed.
NET T1 fail
The unit failed to internally loop data on the network T1 circuit.
DTE T1 fail
The unit failed to internally loop data on the DTE T1 (DSX-1)
circuit.
DSU fail
The unit failed to internally loop data on the DSU.
DSU Port
n fail
Port’s integrated circuitry failed to pass device internal testing.
Modem fail
Unit failed to internally loop data through the modem circuit.
Unknown Exp Dev
The unit is not able to recognize the expansion device connected
to the main circuit card.
Failure
xxxxxxxx
An 8-digit hexadecimal failure code is provided for service
personnel.
F1
F2
F3
STest Health:
Passed
Содержание 3160-A3
Страница 16: ...About This Guide x February 2001 3160 A2 GB21 90...
Страница 24: ...1 Introduction 1 8 February 2001 3160 A2 GB21 90...
Страница 100: ...3 Operation 3 66 February 2001 3160 A2 GB21 90...
Страница 142: ...A Front Panel Menu A 2 February 2001 3160 A2 GB21 90...
Страница 198: ...C Configuration Options C 54 February 2001 3160 A2 GB21 90...
Страница 246: ...E SNMP MIB Objects E 32 February 2001 3160 A2 GB21 90...
Страница 280: ...H Asynchronous Terminal Operation H 24 February 2001 3160 A2 GB21 90...
Страница 282: ...I Equipment List I 2 February 2001 3160 A2 GB21 90...