
CC-LINK Network Communication
WUME-SCHG1C-4
4-9
■
Remote output RY (Mode 1 master station → Communication unit)
This is a write-only register for output from the master station to the communication unit in units
of bits.
Before using mode 1, be sure to configure the “page” settings.
For details, refer to
<Remote output RY>
RY
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
+00
Sensor response data switching request
Not used
Command
request
Not used Error
code Not used Command
Sensor
head
value
Calcu-
lated
value
Normal
mea-
sured
value
Judg-
ment
value
Write
flag
Send
request
+10
Not used
Page
Page 3 Page 2 Page 1
+20 Not used
External input 1 (IN1)
Slave
unit 14
Slave
unit 13
Slave
unit 12
Slave
unit 11
Slave
unit 10
Slave
unit 9
Slave
unit 8
Slave
unit 7
Slave
unit 6
Slave
unit 5
Slave
unit 4
Slave
unit 3
Slave
unit 2
Slave
unit 1
Master
unit
+30 Not used
External input 2 (IN2)
Slave
unit 14
Slave
unit 13
Slave
unit 12
Slave
unit 11
Slave
unit 10
Slave
unit 9
Slave
unit 8
Slave
unit 7
Slave
unit 6
Slave
unit 5
Slave
unit 4
Slave
unit 3
Slave
unit 2
Slave
unit 1
Master
unit
+40 Not used
External input 3 (IN3)
Slave
unit 14
Slave
unit 13
Slave
unit 12
Slave
unit 11
Slave
unit 10
Slave
unit 9
Slave
unit 8
Slave
unit 7
Slave
unit 6
Slave
unit 5
Slave
unit 4
Slave
unit 3
Slave
unit 2
Slave
unit 1
Master
unit
+50
Not used
+60
+70
Not used
Error clear
request
Setting
initial-
ization
request
Initializa-
tion done
Not used
<Setting details>
Name
Device No.
Description
Command request
Send request
RY[00]
Send command to controller request bit.
When this bit is set, a command is sent.
To send a subsequent command, clear the bit and then set again.
Write flag
RY[01]
To execute a read command, clear this bit.
To execute a write command, set this bit.
RY[00]: Set before a send request.
Sensor response data switching request (*1) (*2)
Judgment value
(*3)
RY[08]
Change to judgment value mode.
When the bit is set, the mode changes to judgment value mode.
Normal mea-
sured value (*3) RY[09]
Change to normal measured value mode.
When the bit is set, the mode changes to normal measured value mode.
Calculated value
(*3)
RY[0A]
Change to calculated value mode.
When the bit is set, the mode changes to calculated value mode.
Sensor head
value (*3)
RY[0B]
Change to sensor head value mode.
When the bit is set, the mode changes to sensor head value mode.
Command
RY[0C]
Change to command mode.
When this bit is set, changing to command mode and sending com-
mands is allowed.
Set before a command request (RY[00]: send request).
Error code
RY[0E]
Change to error mode.
When this bit is set, the mode changes to error mode.
Page1 to page3
(*4) (*5)
RY[10] to [12]
Changes the controller assignment in the memory map.
When this bit is set, the controller assignment changes to the assign-
ment of the set page settings.
External input 1
(IN1) (*6)
RY[20] to [2E]
Controls external input 1 on the controller.
When this bit is set, external input 1 turns ON.
Содержание SC-HG1-C
Страница 2: ...WUME SCHG1C 4 2 MEMO ...
Страница 8: ...WUME SCHG1C 4 8 MEMO ...
Страница 16: ...WUME SCHG1C 4 1 8 MEMO ...
Страница 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Страница 22: ...WUME SCHG1C 4 2 6 MEMO ...
Страница 106: ...WUME SCHG1C 4 4 72 MEMO ...
Страница 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Страница 110: ...WUME SCHG1C 4 5 4 MEMO ...
Страница 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Страница 114: ...WUME SCHG1C 4 6 4 MEMO ...
Страница 115: ...7 1 7 Maintenance 7 1 Maintenance and Inspection 7 2 7 1 1 Maintenance cautions 7 2 7 1 2 Main inspection items 7 2 ...
Страница 124: ...WUME SCHG1C 4 8 8 MEMO ...
Страница 125: ...Revision History 1st edition 1 27 2017 2nd edition 9 8 2017 3rd edition 9 30 2019 4th edition 12 1 2019 ...
Страница 126: ... MEMO ...
Страница 127: ... MEMO ...