CC-LINK Network Communication
WUME-SCHG1C-4
4-70
●
HG-TC
series
For details on Response Parameter adress, refer to
“4-10-2 HG-T series command list”
Response parameter
Measures
Error code (Note 1) measurement alarm
(Note 1)
Notifi
-
cation
Sensor head unconnected
Status check
E200
–
Connected sensor head incompat-
ible
Status check
E230
–
Connected unit count check error
Status check
E160
(For master units only) –
NPN / PNP output type mixture error Status check
E100
(For master units only) –
Calculated unlit count error
Status check
E110
(For master units only) –
Copy executionerror
( Slave unit problem)
Status check
E170
(For master units only) –
Detection capability limit (obtained
edge information) (Note 2)
Sensing object check
–
Measurement alarm 1
The amount of entering light is too
much due to the influences of ambi
-
ent light, etc. (Note 2)
Status check
–
Measurement alarm 1
The amount of entering light de-
creases due to stain on the detection
surface, beam axis misalignment, etc.
Sensing object check
–
Measurement alarm 2
The specified measurement direc
-
tion differs from the insertion direc
-
tion of the detected object
Status check /
Sensing object check –
Measurement alarm 2
Cau-
tion
Controller cumulative run time limit
exceeded(87,600 hours)
Controller replacement –
–
Sensor head cumulative run time
limit exceeded (87,600 hours)
Sensor head replacement –
–
Controller memory saving count limit
exceeded (1,000,000 times)
Controller replacement –
–
Sensor head memory saving count
limit exceeded
(for receivers only, 1,000,000 times)
Sensor head replacement –
–
Fault
Controller memory function damaged Controller replacement E600 / E610 / E620 –
Sensor head memory function damaged Sensor head replacement E630 (For receivers only)
E640 (For emitters only) –
Output section short-circuit error
Status check /
Replacement
E700
–
Detection circuit damaged
Sensor head replacement E240
–
System error
Controller replacement E900 / E910 / E911 /
E912 / E920
–
Notes: 1) Error codes and alarms are displayed on
HG-TC
□ controllers.
2) If “Alarm condition selection (ALM.CND)” is set to “Hold last value (HOLD)”, Measurement alarm 1 is
not notified.
Содержание SC-HG1-C
Страница 2: ...WUME SCHG1C 4 2 MEMO ...
Страница 8: ...WUME SCHG1C 4 8 MEMO ...
Страница 16: ...WUME SCHG1C 4 1 8 MEMO ...
Страница 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Страница 22: ...WUME SCHG1C 4 2 6 MEMO ...
Страница 106: ...WUME SCHG1C 4 4 72 MEMO ...
Страница 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Страница 110: ...WUME SCHG1C 4 5 4 MEMO ...
Страница 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Страница 114: ...WUME SCHG1C 4 6 4 MEMO ...
Страница 115: ...7 1 7 Maintenance 7 1 Maintenance and Inspection 7 2 7 1 1 Maintenance cautions 7 2 7 1 2 Main inspection items 7 2 ...
Страница 124: ...WUME SCHG1C 4 8 8 MEMO ...
Страница 125: ...Revision History 1st edition 1 27 2017 2nd edition 9 8 2017 3rd edition 9 30 2019 4th edition 12 1 2019 ...
Страница 126: ... MEMO ...
Страница 127: ... MEMO ...