CC-LINK Network Communication
WUME-SCHG1C-4
4-43
Command
Attribute
Name
Response/Setting parameter
HG-T
Series
0x0309
R/W Alarm state selection
(ALM.CND)
0: HOLD (hold previous value)
1: ALARM (alarm output)
0x030A to 0x030B
-
System reserved
Do not use.
0x030C
R/W Stain check (STA.CHK)
0: Stain check OFF (OFF)
1: Low sensitivity setting ON (LOW)
2: High sensitivity setting ON (HIGH)
3: User setting ON (USER)
0x030D
R/W Stain threshold (STA.THR)
50 to 95
0x030E
R/W Hold setting (HOLD)
Set the sum of the values below according to
the states of the measurement mode and trigger
mode settings.
• Measurement mode (MEAS)
0x0000 = Sample hold
0x1000 = Peak hold
0x2000 = Bottom hold
0x3000 = Peak to peak hold
0x4000 = Peak to peak hold P-P/2
0x5000 = NG hold
• Trigger mode (TRIG)
0x000 = One-shot
0x100 = Hold
0x030F to 0x0315
-
System reserved
Do not use.
0x0316
R/W
Calculation mode (MODE) /
Calculation application selec-
tion (APPLI)
0: No calculation
1: Maximum value (MAX)
2: Minimum value (MIN)
4: Average value (AVERAG)
5: Standard difference (STAND)
8: Thickness/Width (THICK)
0x0317
R/W Copy select individual
(CPY.SEL)
0 = Not target / 1 = Target
For each target, set the bit to 0 or 1.
Bit 0: Operation mode selection
Bit 1: Measurement direction
Bit 2: HIGH set value
Bit 3: LOW set value
Bit 4: Hysteresis
Bit 5: Teaching type
Bit 6: Tolerance setting
Bit 7: Preset value
Bit 8: Preset data selection
Bit 9: Preset save
Bit 10: Reference waveform save
Bit 11: Average count
Bit 12: Output pattern
Bit 13: Analog output selection
Bit 14: Hold setting
Bit 15: External input
Bit 16: External output
Bit 17: External output delay timer selection
Bit 18: Number of digits displayed
Bit 19: Eco mode
Bit 20: Alarm
Bit 21: Key lock setting selection
0x0318
-
System reserved
Do not use.
0x0319
W
Copy execution (CPY.EXE)
Execute copying.
Specify "0".
0x031A
R/W Copy lock (LOCK)
0: Copy lock OFF
1: Copy lock ON
0x031B
R/W Bank save selection
(BNK.DAT)
0: All
1: HIGH set value, LOW set value
2: HIGH set value, LOW set value, preset value
Содержание SC-HG1-C
Страница 2: ...WUME SCHG1C 4 2 MEMO ...
Страница 8: ...WUME SCHG1C 4 8 MEMO ...
Страница 16: ...WUME SCHG1C 4 1 8 MEMO ...
Страница 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Страница 22: ...WUME SCHG1C 4 2 6 MEMO ...
Страница 106: ...WUME SCHG1C 4 4 72 MEMO ...
Страница 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Страница 110: ...WUME SCHG1C 4 5 4 MEMO ...
Страница 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Страница 114: ...WUME SCHG1C 4 6 4 MEMO ...
Страница 115: ...7 1 7 Maintenance 7 1 Maintenance and Inspection 7 2 7 1 1 Maintenance cautions 7 2 7 1 2 Main inspection items 7 2 ...
Страница 124: ...WUME SCHG1C 4 8 8 MEMO ...
Страница 125: ...Revision History 1st edition 1 27 2017 2nd edition 9 8 2017 3rd edition 9 30 2019 4th edition 12 1 2019 ...
Страница 126: ... MEMO ...
Страница 127: ... MEMO ...