Before You Start
CPU unit
MEWNET-F can be used by the combination of the CPU unit of FP3 and the following remote I/O master
unit.
As for FP3, use the CPU unit of Ver. 2.0 or later.
The remote I/O control is not available with the CPU unit of a version older than Ver. 2.0.
CPU unit
Remote I/O master unit
FP2/FP2SH
For FP2 (AFP2720)
FP3 Ver. 2.0 or later
For FP3 (AFP3742)
FP10SH
For FP3 (AFP3742)
Number of connected slave stations
-
A maximum of 32 slave stations can be connected to one master unit. The total number of occupied I/O
points of slave stations should be up to the number of I/O points that each master unit can use.
-
When using slave units, note that the number of units may be limited due to the restriction on number of
slots.
I/O to be used
-
The I/O to be used for the slave stations of MEWNET-F is automatically allocated according to the
order in which master units are installed or slave station number.
-
I/O numbers in the following ranges are allocated at the factory setting.
Master in network
No. of points
I/O No.
First master unit
Second master unit
Third master unit
Forth master unit
512 points
256 points
128 points
128 points
640 to 95F
960 to 111F
1120 to 119F
1200 to 127F
-
More number of points can be used on MEWTNET-F by changing the factory setting. Tool software is
required to change the setting. For changing the setting, specify in the following ranges.
1. Up to 4096 points of I/O can be used for one master unit.
In case of the CPU unit of FP2/FP3, up to 2048 points can be used.
In case of FP3 master unit Ver. 1.4 or older, up to 1024 points can be used.
2. Numbers that excced the maximum number of controllable I/O points of CPU unit cannot be set.
- I/O can be allocated by changing the setting regardless of slave station numbers or order in which
units are installed. Tool software is required to change the setting.
Slave unit
-
There are differences between FP2 slave I/O unit and FP3 slave I/O unit.
Especially, confirm thoroughly when replacing FP3/FP10SH system.
1. FP2 slave I/O unit should be installed in the installation position for a CPU unit on the
backplane as well as FP3 slave I/O unit.
If it is installed in the installation position for an I/O unit, it may be damaged due to electric stress.
Reference:
<1.2 System Configuration>
2. There are advanced units which cannot be used for the slave station system.
Reference:
<1.2.3 Advanced Units Not to be Used for Slave Station System of “MEWNET-F”>
Содержание MEWNET-F
Страница 9: ...Chapter 1 Functions and Restrictions of the Unit ...
Страница 19: ...Chapter 2 Part Names and Functions ...
Страница 40: ...2 22 ...
Страница 41: ...Chapter 3 Unit Specifications ...
Страница 52: ...3 12 ...
Страница 53: ...Chapter 4 Installation and Wiring ...
Страница 62: ...4 10 ...
Страница 63: ...Chapter 5 Connection for the Remote I O System ...
Страница 75: ...Chapter 6 Remote I O Map ...
Страница 84: ...6 10 ...
Страница 85: ...Chapter 7 Operation Modes for Controlling MEWNET F ...
Страница 97: ...Chapter 8 Control by MEWNET F ...
Страница 108: ...8 12 Flowchart ...
Страница 110: ...8 14 ...
Страница 111: ...Chapter 9 Troubleshooting ...
Страница 120: ...9 10 ...
Страница 121: ...9 11 9 5 2 When the ALARM LED is ON ...
Страница 122: ...9 12 9 5 3 When the Communication LED on the Master Unit does Not Flash Normally ...
Страница 123: ...9 13 When the COMM LED is OFF ...
Страница 124: ...9 14 When the COMM LED is ON ...
Страница 125: ...9 15 9 5 4 When the Communication LED on a Slave Station does Not Flash Normally ...
Страница 126: ...9 16 When the COMM LED is OFF ...
Страница 127: ...9 17 When the COMM LED is ON ...
Страница 128: ...9 18 9 5 5 When the CPU does Not Operate ...
Страница 129: ...9 19 9 5 6 When the Input Output Function of a Slave Station does Not Work ...
Страница 130: ...9 20 9 5 7 When the Memory Access Function for the Advanced Unit s Memory does Not Work ...
Страница 134: ...9 24 ...
Страница 135: ...Chapter 10 Dimensions ...
Страница 136: ...10 2 10 1 FP2 Multi wire Link Unit AFP2720 10 2 FP3 Remote I O Master Unit AFP3742 ...
Страница 137: ...10 3 10 3 FP2 Remote I OSlave Unit AFP2745 10 4 FP3 Remote I OSlave Unit AFP3745 ...
Страница 141: ...10 7 10 8 FP0 I O Link Unit AFP0732 ...
Страница 142: ...10 8 ...
Страница 143: ...Chapter 11 Appendix 1 I O Link With FP1 ...
Страница 147: ...11 5 11 3 Part Names and Functions ...
Страница 159: ...Chapter 12 Appendix 2 I O Link With FP0 ...
Страница 164: ...12 6 ...
Страница 165: ...Record of changes Manual No Date Desceiption of changes FAF 35E 1 Mar 2008 First edition ACG M0028 1 FAF 35 13 ...
Страница 166: ......
Страница 167: ......
Страница 168: ...FAF 35E 1 200803 http www mew co jp ac e fasys 2008 ...