11-14
3. Exchange I/O information between FP1 programmable controllers on the MEWNET-F network
-
I/O information cannot be exchanged directly between the FP1 programmable controllers connected to
the [MEWNET-F].
-
When I/O information is exchanged between FP1programmable controllers, the program in the CPU of
the master station system is used.
In the example below, if the execution condition is met on the FP1 which is the slave station number 1,
an instrucation will be executed on the FP1 and also the FP1 which is the slave station number 2.
The execution condition on the FP1 (No. 1): ON
→
Execute an instruction on the I/O link unit No. 1.
↓
Turn ON the Y relay for the I/O link.
↓
X relay of the master station FP2/FP2SH/FP3/FP10SH: ON
↓
Turn ON the Y relay corresponding to the I/O link unit No. 2.
↓
X relay for the I/O link of the FP1 (No. 2)
→
Execute an instruction on the I/O link unit No. 2.
Содержание MEWNET-F
Страница 9: ...Chapter 1 Functions and Restrictions of the Unit ...
Страница 19: ...Chapter 2 Part Names and Functions ...
Страница 40: ...2 22 ...
Страница 41: ...Chapter 3 Unit Specifications ...
Страница 52: ...3 12 ...
Страница 53: ...Chapter 4 Installation and Wiring ...
Страница 62: ...4 10 ...
Страница 63: ...Chapter 5 Connection for the Remote I O System ...
Страница 75: ...Chapter 6 Remote I O Map ...
Страница 84: ...6 10 ...
Страница 85: ...Chapter 7 Operation Modes for Controlling MEWNET F ...
Страница 97: ...Chapter 8 Control by MEWNET F ...
Страница 108: ...8 12 Flowchart ...
Страница 110: ...8 14 ...
Страница 111: ...Chapter 9 Troubleshooting ...
Страница 120: ...9 10 ...
Страница 121: ...9 11 9 5 2 When the ALARM LED is ON ...
Страница 122: ...9 12 9 5 3 When the Communication LED on the Master Unit does Not Flash Normally ...
Страница 123: ...9 13 When the COMM LED is OFF ...
Страница 124: ...9 14 When the COMM LED is ON ...
Страница 125: ...9 15 9 5 4 When the Communication LED on a Slave Station does Not Flash Normally ...
Страница 126: ...9 16 When the COMM LED is OFF ...
Страница 127: ...9 17 When the COMM LED is ON ...
Страница 128: ...9 18 9 5 5 When the CPU does Not Operate ...
Страница 129: ...9 19 9 5 6 When the Input Output Function of a Slave Station does Not Work ...
Страница 130: ...9 20 9 5 7 When the Memory Access Function for the Advanced Unit s Memory does Not Work ...
Страница 134: ...9 24 ...
Страница 135: ...Chapter 10 Dimensions ...
Страница 136: ...10 2 10 1 FP2 Multi wire Link Unit AFP2720 10 2 FP3 Remote I O Master Unit AFP3742 ...
Страница 137: ...10 3 10 3 FP2 Remote I OSlave Unit AFP2745 10 4 FP3 Remote I OSlave Unit AFP3745 ...
Страница 141: ...10 7 10 8 FP0 I O Link Unit AFP0732 ...
Страница 142: ...10 8 ...
Страница 143: ...Chapter 11 Appendix 1 I O Link With FP1 ...
Страница 147: ...11 5 11 3 Part Names and Functions ...
Страница 159: ...Chapter 12 Appendix 2 I O Link With FP0 ...
Страница 164: ...12 6 ...
Страница 165: ...Record of changes Manual No Date Desceiption of changes FAF 35E 1 Mar 2008 First edition ACG M0028 1 FAF 35 13 ...
Страница 166: ......
Страница 167: ......
Страница 168: ...FAF 35E 1 200803 http www mew co jp ac e fasys 2008 ...