1.4
Mechanism of Processing
1-9
1.4.2 Operation When Power Supply Turns On
•
FP7 MC Unit reads the "parameters for FP7 MC Unit" stored in the FROM (FlashROM)
within the unit and sets them in the memory areas within the unit.
•
FP7 MC Unit starts the communication with the slaves (servo amplifiers) connected to
EtherCAT. Once the links with the slaves (servo amplifiers) are established, it is notified to
FP7 CPU Unit by the input relay (X0).
•
When the mode setting switch is set to RUN mode, FP7 CPU Unit checks that the state of
the FP7 system is correct, switches the mode to RUN mode, and executes user programs.
1.4.3 Start/Stop by User Programs
•
For FP7 MC Unit, main I/O signals to execute various controls (such as positioning, JOG
operation, home return, and stop) are allocated to the unit memories (UM).
•
In the unit memories (UM) "output control area", request signals to perform start and stop
controls are allocated. In the unit memories "Input control area", flags such as busy flag and
error flag to check the start conditions are allocated.
•
FP7 MC Unit controls operations by reading or writing data from or to these unit memories.
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......