13.12
Connection with Slave Encoder Input Device
13-45
5. The "Used parameter setting" window is displayed. Set an index number for
the CoE object of the target slave device in "Position actual value (actual
position information area of motor)".
13.12.3
Monitor Operation
The input from the encoder can be counted. After that, it can be monitored by the AM current
value by requesting to turn on the servo of the axes for the encoder registered in FP7 MC Unit.
●: Available,
-: Not available
Axis no.
Unit
memory
no. (Hex)
Name
Default
Description
R
W
1
UM 02654
-UM 02655
AMP
current
value
(Absolute
coordinate)
K0
Stores the current value based on a mechanical
origin in pulse units. It will be reset to “0” on the
completion of home return. The value will not be
updated when the current value update function is
executed.
Unit: pulse
●
-
1
UM 02656
-UM 02657
Current
value after
unit
conversion
(Logic
system
coordinate)
K0
Stores the current value based on an electric
origin (value set as home position coordinate).
Stores values converted with the unit system
(pulse, μm, inch, degree) selected in the axis
parameter as integer. When the home return is
completed, the value set as home position
coordinate will be stored. When “0” is set as home
position coordinate, it will be reset to “0”. This area
is also updated when the current value update
function is used.
●
-
(Note): The count range of encoder input is unsigned 32 bits (0 to 4,294,967,295).
Set an index number for each counter
by switching the axis number.
Set the index number for the
CoE object of the counter
current value of the slave device.
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......