Creation
of User Programs
7-2
7.1 How to Create User Programs
7.1.1 Basic Configuration of Program
The user programs which control FP7 MC Unit are created by the tool software "FPWIN GR7".
•
To support the multi-axis control through network, for FP7 MC Unit, main input and output
signals required for the control are allocated to the unit memories (input control area/output
control area).
•
For various controls, the processes of reading flags from unit memories (input control area)
and writing operation results to unit memories (output control area) are created as programs.
They are executed to transfer data between units at the time of I/O refresh.
•
As exceptions, the "link establishment flag (X0)" for storing the link establishment of network
and "system stop request (Y0)" for stopping the whole system are allocated to the area of
I/O signals (XY).
Configuration of program
Item
Description
①
Reading from unit
memories UM (input
control area)
Reads information required for confirming states from the unit memories (input
control area) to an arbitrary operation memories (such as internal relay area
WR).
Example) Connection confirmation flag, servo lock flag, busy flag, error
annunciation flag
②
Servo control
Outputs the requests for the servo on and servo off controls to the operation
memories (such as internal relay area WR).
③
Start enabled control
Checks the states of read flags if each control (such as position control, JOG
operation, home return) can be started, and outputs the start enabled states to
internal relays.
④
Various control
programs (such as
position control, JOG
operation, home return)
Checks the results of start enabled controls, and outputs the start requests for
position control, JOG operation or home return to the operation memories (such
as internal relays).
⑤
Writing to unit
memories UM (output
control area)
Writes the results of the operation memories (such as internal relay area) in
which the above operation results are reflected to the unit memories (output
control area).
Example) Startup of positioning, JOG operation, or home return, stop control
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......