13.2
Current Value Update
13-3
13.2 Current Value Update
The current value update is a function to set the "current value after unit conversion" stored in
the unit memories within FP7 MC Unit to an arbitrary value.
•
A value is set in the current value update coordinate area (UM005A0 to UM0065F) in the
unit memories as a current value using a user program.
•
The "current value after unit conversion" of each axis information area is changed to the
specified current value by turning on the bit of a target axis in the current value update
request flag area (UM00590 to UM00595).
Program example
When changing the current position of the 1st axis to 100,000, the following figure shows a
program to preset an arbitrary value "K100000" in the current value update area in the unit
memories and update the value for the current value after unit conversion of 1st axis.
R0
(
)
DF
MV.US
S1
:
UM00590
H1
MV.SL
S1:UM005A0
K100000
KEY POINTS
•
The "current value after unit conversion" area in the unit memories is
updated by the "current value update" function. Values in the "AMP current
value" area are not updated.
•
An integer equivalent to the current value after unit conversion is set to the
unit memory.
Example) When the unit is um (0.1 um), set to "10000" for making it be
1000.0 um.
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......