Troubleshooting
15-12
FP7 MC
error code
A5B error no.
Description
Main
Sub
0051H
81
0
Synchronization cycle error protection
81
1
Mailbox error protection
81
4
PDO watchdog error protection
81
5
DC error protection
81
6
SM event mode error protection
81
7
SyncManager2/3 error protection
0054H
84
3
Synchronous establishment initialization error protection
0055H
85
0
TxPDO assignment error protection
85
1
RxPDO assignment error protection
85
2
Lost link error protection
85
3
SII EEPROM error protection
0057H
87
0
Compulsory alarm input protection
0058H
88
0
Main power under voltage protection (AC insulation
detection 2)
88
1
Control mode setting error protection
88
2
ESM requirements during operation error protection
88
3
Improper operation error protection
005BH
91
1
Command error protection
005CH
92
0
Encoder data recovery error protection
92
1
External scale data recovery error protection (Not
supported)
005DH
93
0
Parameter setting error protection 1
93
2
Parameter setting error protection 2
93
3
External scale connection error protection (Not supported)
93
7
Parameter setting error protection 5
005EH
94
2
Home position return error protection 2
005FH
95
0
Motor automatic recognition error protection
95
1
Motor automatic recognition error protection
95
2
Motor automatic recognition error protection
95
3
Motor automatic recognition error protection
95
4
Motor automatic recognition error protection
0062H
98
4
Unusual communication IC initialization protection
-
Other numbers
Other error protections
(Note): Refer to the latest instruction manual and technical materials of the servo amplifier.
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......