Troubleshooting
15-4
15.1.4 Error and Warning Logs
FP7 MC Unit has log areas to store error and warning codes in its unit memories.
•
Once an error/warning occurs, the error/warning code will be stored in the log area of the
axis that the error occurred.
•
When an error/warning that is not related to the axes occurs, such as a failure in the unit, the
error/warning code will be stored in the log areas of all axes.
•
In the data monitor or tool operation dialog box on CMI, only the latest error and warning
codes of each axis can be confirmed.
•
For referring the error and warning logs for each axis, read the following unit memory from
the PLC.
Configuration of log areas
Classification
Classification
Function
Error
annunciation &
clear area
Error clear individual
axis setting
No. of occurrences of
errors
The number of occurred errors is stored.
Error code buffer 1
Up to eight error codes per axis are stored.
Eight-digit hex codes are stored as error codes.
The buffer 1 is always the latest code. Error codes are stored in
the occurrence order from the buffer 1.
------
Error code buffer 8
Warning
annunciation &
clear area
Warning clear individual
axis setting
No. of occurrences of
warnings
The number of occurred warnings is stored.
Warning code buffer 1
Up to eight warning codes per axis are stored.
The buffer 1 is always the latest code. Warning codes are stored
in the occurrence order from the buffer 1.
------
Warning code buffer 8
REFERENCE
•
For details of the log areas, refer to "16.5.10 Error Annunciation and Clear
Area" and "16.5.11 Warning Annunciation and Clear Area".
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......