9.5
Electronic Clutch Function
9-25
9.5.5 Phase Specification Clutch OFF Function
What is phase specification clutch OFF function?
•
The "phase specification clutch OFF function" is a function for disconnecting an electronic
clutch (OFF) at an arbitrarily specified phase. For stopping or starting at the same phase
repeatedly, the control without variance can be performed. This function is available since
FP7 MC Unit Ver. 1.20.
•
However, select "Direct" for the clutch OFF method. When selecting "Slip", variation in stop
position is caused because it stops after the elapse of a slip time from a stop phase
arbitrarily set.
Clutch OFF method (Direct)
When performing the OFF request by the I/O signal, the clutch off operation will be executed
regardless of phase.
OFF
ON
100%(0%)
0%
50%
t
t
Phase after clutch
control
I/O X clutch
connection
state annunciation
Disconnected
Connected
Slave axis
(e.g. Rotary cutter)
Clutch request is OFF.
Clutch is OFF.
I/O Y clutch ON
request
Master axis
Current value after
unit conversion
Phase
Current value
Using the "phase specification clutch off function" disconnects a clutch when the phase
reaches the set phase (0%) after the clutch off request by the I/O signal.
OFF
ON
100%(0%)
0%
50%
t
t
It does not turn OFF until
the phase after clutch control
reaches the set value.
Clutch OFF setting phase
Current value
Phase after clutch
control
I/O X clutch
connection
state annunciation
Disconnected
Connected
Phase
Slave axis
(e.g. Rotary cutter)
I/O Y clutch ON
request
Master axis
Current value after
unit conversion
(Note 1): The above figure shows the case that the both clutch ON request and OFF request are set to "Level". Also,
either "Leading edge" or "Trailing edge" can be selected.
(Note 2): The above figure shows the case that the clutch off setting ratio is set to “0%”. It can be set to 0 to 99%.
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......