Names
and Functions of Parts
2-4
2.1.3 ESM (State Transition Diagram)
Init
Pre
-Operational
Safe-Operational
Operational
(IP)
(PI)
(SI)
(SP)
(SO)
(OS)
(PS)
(OP)
(OI)
Reference: Created by us based on "Operating principle of EtherCAT" issued by ETG
ESM state
(Abbr.)
SDO
communication
Send/Receive
PDO
communication
(S
→
M)
PDO
communication
(M
→
S)
Description
Init
Not available
Not available
Not available
The state that the
communication part is
being initialized and data
cannot be sent/received
using SDO (Mailbox) and
PDO.
Pre-Operational
(
PreOP
)
Available
Not available
Not available
The state that data can be
sent/received using SDO
(Mailbox).
Safe-Operational
(
SafeOP
)
Available
Available
Not available
The state that data can be
sent/received using SDO
(Mailbox) and data can be
sent (from slaves to
master) using PDO.
Operational
(
OP
)
Available
Available
Available
The state that data cannot
be sent/received using
SDO (Mailbox) and PDO.
(Note): S: Slave, M: Master
What is ESM (EtherCAT State Machine)?
•
ESM shows the state of the communication determined as the specifications of EtherCAT.
•
The state transition is performed between FP7 MC Unit and Servo Amplifier A6B/A5B, any
settings or programming by users are not required.
Confirmation method
•
The state of ESM can be confirmed by the operation monitor LED "EC RUN" on the front
side of FP7 MC Unit.
•
When communication is performed, "Operational (OP)" (EC RUN LED) is on, and the input
relay “X0 (Link establishment)" of FP7 MC Unit is on.
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......