16.9
Unit
Memories (Positioning Operation Change Setting Area)
16-83
16.9.2 Positioning Speed/Movement Amount Change Parameter
●
:
Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name
Default Description
R
W
1
UM 66940
Reserved for
system
-
-
-
-
1
UM 66941
Positioning
speed
change
function
change mode
selection
H0
Area for setting the range of the positioning speed
change.
00H: Active table only
01H: Active table to E-point (until the completion of
the operation)
When setting any other values, the unit operates as
the setting of 00H (Active table only).
1
UM 66942
-UM 66943
Positioning
speed
change
function
speed value
U100
Area for setting a change speed for changing the
positioning speed.
Range: 1 to 2,147,483,647
Any other settings will be errors.
The ranges vary depending on the unit settings as
below.
pulse: 1 to 2,147,483,647 pps
μm: 1 to 2,147,483,647 μm/s
inch: 0.001 to 2,147,483.647 inch/s
degree: 0.001 to 2,147,483.647 rev/s
-
UM 66944
-UM 66949
Reserved for
system
-
-
-
-
1
UM 6694A
-UM 6694B
Positioning
movement
amount
change
function
movement
amount
K0
Area for setting a change movement amount for
changing the positioning movement amount.
Range: -2,147,483,648 to 2,147,483,647
The ranges vary depending on the unit settings as
below.
pulse:-2,147,483,648 to 2,147,483,647 pulses
μm (0.1 μm):
-
214,748,364.8 to 214,748,364.7 μm
μm (1 μm):
-
2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch): -21,474.83648 to 21,474.83647
inches
inch (0.0001 inch): -214,748.3648 to 214,748.3647
inches
degree (0.1 degree): -214,748,364.8 to
214,748,364.7 degrees
degree (1 degree) : -2,147,483,648 to
2,147,483,647 degrees
Any other settings will be errors.
Содержание AFP7MC16EC
Страница 1: ......
Страница 19: ...1 Unit Functions and Restrictions ...
Страница 28: ...Unit Functions and Restrictions 1 10 ...
Страница 29: ...2 Names and Functions of Parts ...
Страница 33: ...3 Installation and Wiring ...
Страница 47: ...4 Basic Procedure ...
Страница 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Страница 97: ...6 Data Transfer to MC Unit and Test Operation ...
Страница 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Страница 123: ...7 Creation of User Programs ...
Страница 131: ...8 Automatic Operation Position Control ...
Страница 143: ...8 2 Interpolation Control 8 13 ...
Страница 193: ...9 Automatic Operation Synchronous Control ...
Страница 251: ...10 Manual Operation JOG Operation ...
Страница 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Страница 263: ...11 Manual Operation Home Return ...
Страница 277: ...12 Stop Functions ...
Страница 286: ...Stop Functions 12 10 ...
Страница 287: ...13 Supplementary Functions ...
Страница 336: ...Supplementary Functions 13 50 ...
Страница 337: ...14 CMTimeChart Monitor ...
Страница 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Страница 365: ...15 Troubleshooting ...
Страница 396: ...Troubleshooting 15 32 ...
Страница 397: ...16 Specifications ...
Страница 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Страница 502: ......
Страница 503: ......
Страница 504: ......