Page
165
of
248
The downloaded data is in Sutron Standard CSV format and can be easily displayed using Sutron’s
GRAPHER program (downloadable from
) or common spreadsheet/word processing
programs.
You can download the whole log or only parts of it. You may specify the start date and optionally the end
date for the downloaded data. You may also ask for data from the last X days. Downloading via the USB
thumb drive will download all the new data since last download.
There are options to download only data from a specific measurement. Events can be excluded from the
log download.
The station remembers the last log download and will allow downloads since last download. This means
that the only parts of the log downloaded are those that have not been previously downloaded.
14.2
Log Events
Occasionally, the system will log events. Events are used to help in troubleshooting and station
maintenance.
The following are some of the actions that will cause the station to log an event:
Setup change (when any setting is changed)
Log download (when the log is downloaded)
Reset (log contains reset type and count)
Errors (such as low battery and sensor failure)
Before cal and after cal (logged when the user sets the sensor level to record the value before
and after the calibration)
Log in events (if password is enabled), including failure to log in.
Telemetry events (transmission made, message received, etc.)
Alarm events
The setting
Log Daily Values
) determines whether certain log events are logged
every day before midnight.
The setting
Log Diagnostics
(command line only) sets the software to log diagnostic information.
14.3
Logged Time
Measurements are not instant. Once initiated, a measurement takes the user-defined averaging time, plus
some overhead, to complete.
For measurements without averaging, t
he timestamp of the logged measurement is the time the
measurement was started.
The same is true for transmissions. The timestamp of the transmission is the
time when the transmission process was started, not when it was completed.
Содержание SUTRON XLINK 100
Страница 1: ...Operations Maintenance Manual SUTRON XLINK 100 500 Part No 8800 1217 Rev 8 44 4 January 14 2022...
Страница 230: ...Page 230 of 248...
Страница 247: ...Page 247 of 248...