The format strings you’ll use in each of these setup properties consist of VARIA
BLEs, ESCAPE SEQUENCEs,
and FIELDs. Any text that isn't recognized as a VARIABLE, ESCAPE SEQUENCE, or FIELD, appears as-is in the
final output.
VARIABLE
Replaced with dynamic data from the system. Always upper-case and
typically wrapped in <> characters (date and time variables are not
wrapped in <> characters).
ESCAPE SEQUENCE
Character preceded by "\" character, e.g., "\r\n", for inserting new-
lines, tabs, etc.
FIELD
Replaced with descriptive text from the system. Always upper case.
Log Header Format
The Log Header Format entry defines the header that appears at the top of the file. Its maximum length is
511 bytes. The entry may be blank. The following example defines the standard header (when selected for
inclusion in the download):
STATION,VERSION\r\n<STATION>,<VERSION>\r\nLABEL,TYPE,SLOPE,OFFSET,EQUATION\r\n
Variables that may be used when defining the Log Header Format entry:
<SERIALMICRO>, micro board serial number, e.g., "1242671"
<SERIALPRODUCT>, product serial number, e.g., "32XY812"
<SERIALTX>, transmitter serial number, e.g., "0023354"
<STATION>, station name, e.g., "RedRiver"
<STARTTIME>, directive to use start time of log download when formatting a date-time for use in
the header. The directive itself is not replaced by text, only date-time variables following the
directive.
<STOPTIME>, directive to use stop time of log download when formatting a date-time for use in
the header. The directive itself is not replaced by text, only date-time variables following the
directive.
<VERSION>, firmware version information, e.g., "Sutron XLink..."
Log Descriptor Format
The Log Descriptor Format entry defines measurement settings, and appears after the header, if any. Its
maximum length is 127 bytes. The entry may be blank. The following example defines the standard
descriptor (when selected for inclusion in the download):
<LABEL>,<TYPE>,<SLOPE>,<OFFSET>,<EQUATION>\r\n
Variables that may be used when defining the Log Descriptor Format entry:
<EQUATION>, equation of a measurement, e.g., "X+1"
<LABEL>, label of a measurement, e.g., "Batt"