6.5.2
Setup Status Button
The left header button is the “setup status button”. This button
shows status related to the setup,
including whether the setup is “in
-
sync”, i.e., the same in both LinkComm and the station, and recording
status.
Pressing the setup status button typically prompts the user to take the next logical step towards getting
the setup in-sync between LinkComm and the station, with recording on.
Note: When the setup displayed by LinkComm is the same as the setup in the station,
then we say the setups are “in
-syn
c”. When the setups are not the same, the setup
status button displays a warning sign, and you must send the setup to the station to
get t
he setups “in
-
sync”.
After making changes to the setup locally, you need to send those changes to the station to bring the
setups “in
-
sync”. You do this by pressing the setup status button (or by selecting the main menu item,
“Send Setup to the station”)
.
The following table describes the different states maintained by the setup status button, and describes
what happens when you press the button in each of the states:
LinkComm is connected
to the station, recording is
ON, and the setups are
“in
-
sync”
Press the button to turn off recording. LinkComm
will prompt for confirmation.
A change has been made
to the setup in LinkComm
(it no longer matches the
setup in the station)
Press the button to send setup changes to the
station. LinkComm will prompt for confirmation. If
“Yes”, only the changes required to be “in
-
sync” are
sent. If “No”, LinkComm prompts to retri
eve the
setup from the station, overwriting local changes
The setup in the station is
unknown, and so may
differ from the one
displayed by LinkComm
Press the button to send the setup to the station.
LinkComm will prompt for confirmation. If “Yes”,
LinkComm first sets the setup in the station to
defaults, and then sends the changes required to be
in sync
Recording is OFF in the
station. This means no
Press the button to turn recording ON in the station.
LinkComm will prompt for confirmation