Page
223
of
248
What script function to execute when the script is triggered.
Trigger:
This field determines when the script should run. Options are
Scheduled
Script task will run on a schedule, just like a measurement. The schedule is based on
the settings
Scheduled Interval and Scheduled Time
. Only happens if recording is on.
Bootup
Script will run when the system turns on. It does not matter if recording is on; script
will run at bootup.
Digital 1
Digital 2
Script will trigger when the appropriate digital input changes. System must be
recording.
Alarm In Only
Alarm In And Out
Alarm Out Only
These triggers are associated with alarms; they only happen if recording is on.
Recording On
Recording Off
Script runs when recording is turned on or off.
On User Connect
This happens whenever the customer connects to the station via Wi-Fi, RS-232, USB
cable, Cell Modem (SMS and TCP/IP), Iridium Message, Front Panel Button Press
This trigger will never happen more frequently than once a minute. System does not
need to be recording.
On Button press
Whenever the front panel button is pressed, the script will run, regardless of whether
the system is recording. Please note that
On User Connect
also happens when the
button is pressed.
Do not hold down the button for more than 5 seconds
–
the system will reboot if you
do!
USB Drive Connect
Script will start execution a short while after a USB flash drive is inserted. The system
will first download the log and diagnostics to the USB flash drive (see
). Once those operations complete, the script
will be triggered. Once the script completes, the USB drive will be dismounted for
safe removal.
RS232 Connect DSR
Script executes once the DSR line of the RS232 port is asserted.
System Running
This trigger is for scripts that need to run while recording is on.
If a system boots up and recording is already on, the script would trigger.
Additionally, if recording was off and gets turned on, the script would trigger.