Page
80
of
248
where
<station>
is the name of the station and
<date>
is the current date in yyyymmdd format (e.g.:
"20160204")
Output files are always placed under the full path and given a unique name by appending _01, _02, _03,
..., _99 to the name as necessary.
Regarding Events
By default, plugging in a USB drive will results in only measurement data being downloaded to the
log file. Events are excluded from the log file.
If the following file is located on the USB drive, then the system will download both measurement
and event data:
\Sutron\XLink\IncludeEvents.txt
The file content does not matter. If the file is on the drive, in the specified path, the system
will download both measurements and events.
The rules above apply to software 8.24 and newer. Older versions will always download
both measurements and events to the log file.
Regarding Headers
Logs are downloaded without a header to ease import of log files into other systems.
If the following file is located on the USB drive, then the system will include a header in the
downloaded log file:
\Sutron\XLink\IncludeHeader.txt
The file content does not matter. If the file is on the drive, in the specified path, the system
will download both measurements and events.
The rules above apply to software 8.33 and newer. Older versions will always download
both measurements and events to the log file.
Regarding SD Cards
By default, the lo
g download is done from the station’s on
-board flash memory to the USB drive.
If the station is equipped with an SD card, the log is automatically backed up to the SD card. Because the
SD card may provide more storage space than the on-board flash memory, you may choose to copy the log
data from the SD card instead.
The setting
USB Drive Gets Log From
may be changed to
SD Card
to have the log data copied from the SD
card to the USB drive.
Files Created on the USB Drive
The files created when the USB drive is plugged in include:
log data (ex: "TestStation_log_20161231_02.csv")
diagnostic data (ex: "TestStation_diag_20161231.txt")
setup files (ex: "TestStation_setup_20161231.txt")
results from setup import (ex: "TestStation_setup_results_20161231.txt")
output from script execution (ex: "TestStation_script_results_20161231.txt")