10.8
Transmission Data Content Settings
10.8.1
Tx Data Content
Tx Data Content
indicates which readings to include in the transmission. Each measurement has multiple
Tx Data Content
settings: one for each transmission.
The options are All Logged, Individual, Last, and Exclude.
By selecting
All Logged
, measurements that are logged according to the measurement schedule
are transmitted. Only readings made since the last transmission are included. This setting is
dependent on the
Logging Interval
setting.
Please note that if the system is logging data more frequently due to being in alarms, the
extra data is NOT transmitted. To include extra data created by alarms, please use the
Last
option.
The only data points transmitted are those made according to the measurement time and
logging interval settings.
See below for the
Individual
setting.
Last
means to transmit a set number of the most recent readings (determined by
Number of
Values to Tx
).
Use
Last
for alarm and random transmissions to ensure that the value that caused alarms is
transmitted!
Last
is the only option that may be used to transmit data that is not collected based upon the
measurement schedule.
By selecting
Exclude
, no readings of this measurement are transmitted.
All Since Last Tx
includes all logged data since the last transmission.
All Since Last Tx
selection is
different from
All Logged
in that it ignores measurement scheduling.
All Since Last Tx
will parse
through the log and include every logged entry of the measurement.
This option is useful when the logging interval changes due to alarms or scripts.
This option results in a variable amount of data in the transmission. Only certain
Tx Format
options are suitable for
All Since Last Tx
. Timestamps of transmitted data using SHEF, some
Pseudobinary, and all formats that do not give each reading its own timestamp, may be
incorrect. CSV and MIS will work correctly. Pseudobinary B is not suitable.
With
All Since Last Tx
, all estimates of data content may be incorrect.
With
All Since Last Tx
, newest data in transmission may be at (transmission time -
Sensor
Encoding Time
). Oldest data will be newer than (last transmission time
–
Sensor Encoding
Time
).
Skip First Missing
does not work with
All Since Last Tx
.
10.8.2
Tx Data Time, Interval, and Duration
If
Individual
is selected for
Tx Data Content
, the fields
Tx Data Time
,
Tx Data Interval,
and
Tx Data Duration
will appear, allowing the choice of what data to include in the transmission.
These options may be used to measure and log data more frequently than to include them in
transmissions. They may also be used to transmit redundant data.
Содержание SUTRON XLINK 100
Страница 1: ...Operations Maintenance Manual SUTRON XLINK 100 500 Part No 8800 1217 Rev 8 44 4 January 14 2022...
Страница 230: ...Page 230 of 248...
Страница 247: ...Page 247 of 248...