Page
31
of
248
SDI-12
RS-485
5.4
Connecting the Power Supply
The station provides a means of directly connecting a power supply and a solar panel.
Note: The power supply terminals are removable and serves as the pain power connect/disconnect.
5.4.1
Connecting the Battery
The unit operates off 9-20V.
Note: Even though the unit will operate below 12V some sensors will not operate when the power supply
is below 12V.
A standard 12VDC lead-acid or Gel battery is typically used as the power source. Do not power the unit off
AC power supplies without additional precautions to ensure the power supply is properly rated and the
system is enclosed in a fire protection cabinet.
It is a good practice to make all sensor connections with the unit powered off.
As soon as power is applied, the LED will flash as the unit goes through a self-test sequence. The LED will
flash green when the unit is running, and there are no problems. Red means there is an issue that requires
user intervention. It could mean that there is a problem or that the unit has not been setup.
Battery cable shall have an inline fast fuse to handle current up to 5A