Page
144
of
248
OUTPUT1 tells whether the output is currently on. Possible replies:
Output1 is NOT active
Output1 is ACTIVE
OUTPUT1 ON turns on the output
OUTPUT1 OFF turns off the output
If the digital output is turned off via command line while the system is in alarm, the
system will not turn it back on until it goes out of alarm and later back into alarm.
A measurement setup for a
ROC Alarm
and an
Alarm ROC Interval
set to
Since Last Tx
does not have a going out of alarm state. Those alarms will never turn off the digital
output.
12.4
Cutoff
The system provides several cutoff settings. These settings are used to prevent the system from operating
when the supply voltage or the temperature is outside of the allowed range.
These settings may only be changed via command line; LinkComm does not support them.
12.4.1
Battery Low
The Cutoff System Low and Cutoff Tx Low settings indicate a minimum voltage required for the system to
operate. If the supply voltage goes below the cutoff, the system will go into battery low mode. The
system will not operate normally when in battery low mode.
When the system is below Cutoff System Low:
No measurements are made.
Cell and Iridium modems are shut off.
Wi-Fi is shut off.
All output voltages are shut off:
VREF
+SW POWER
SDI-12 POWER
PROT +12V
When the system is below Cutoff Tx Low:
No transmissions will be made.