549
Display and Setting of Calendar Clock
Section 8-10
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
0
0
Controlled Item
Screen display
Processing priority registration (for NT link (1:N))
Continuous buzzer
Intermittent buzzer (short)
Display history initialization
Not used
Intermittent buzzer (long)
Backlight mode
Screen printing
PT window opening
Numeral/character string input
PT screen switching
Memory table copy execution
Memory table copy type
Alarm history initialization
Not used
1 (ON)
Performed
Registered
Sounded
Sounded
Performed
Sounded
Lit
Performed
Disabled
Disabled
Disabled
Performed
Numeral
Performed
0 (OFF)
Not performed
Canceled
Stopped
Stopped
Not performed
Stopped
Flashing
Not performed
Enabled
Enabled
Enabled
Not performed
Character string
Not performed
Always “0”
Always “0”
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PT Status Control (word n + 3)
The operation for setting the date and time data is described below.
The following explains the operation for copying the numeric value from copy
source numeral memory table A to copy destination numeral memory table No.
254 and from copy source numeral memory table B to copy destination numeral
memory table No. 255. The numeric values in numeral memory tables A and B are
stored in “BCD”.
(1) Set the date and time data in the words where numeral memory table A is allo-
cated (word A and word A+1, in the illustration below).
A + 1
A
Word
15
...
0
15
...
0
Bit
Date
(01 to 31)
Hour
(00 to 23)
Minute
(00 to 59)
Second
(00 to 59)
Contents of setting
(2) Set the date and time data in the words where numeral memory table B is allo-
cated (word B and word B+1, in the illustration below).
B + 1
B
Word
15
...
0
15
...
0
Bit
Not used
(always 00)
Day of week
(00
to
06
Sun.
−
Sat.)
Year
(00
to
99
last 2 digits of
the year)
Month
(01 to 12)
Contents of setting
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...