170
Operations in the System Installer Mode
Section 6-5
6-5-4
Clearing Screen Data
If the screen data has been corrupted and the NT31/NT31C cannot be started nor-
mally, use this function to clear the screen data.
Note that only the screen data is cleared (initialized), and the memory switch set-
tings and the display history/alarm history record data are retained.
Reference
- When this function is used, all of the screen data contents registered in the
NT31/NT31C up to that point are cleared. Check that the created screens are
backed up at the Support Tool before using it.
- The screen data can also be cleared from the System Menu (page 157).
- If the screen data is cleared in the System Installer mode, the message “Screen
Data Corrupted” may be displayed on switching to the RUN mode. If this hap-
pens, initialize the screen data again from the “MEMORY INIT. MENU” screen.
Clear the screen data by following the menu operation from the System Installer
mode menu shown below.
Select “
Erase Screen Data
”.
Select “
Yes
”.
The screen data is cleared. During clear-
ance, the message “Erasing ...” is displayed.
S
If “
Return to Menu
” is selected, the NT31/NT31C returns to the “MEMORY INIT.
MENU” screen without clearing the screen data.
S
If screen data clearance fails, a screen asking if you wish to try again is dis-
played.
On completion of screen data clearance, the NT31/NT31C returns to the System
Installer mode menu screen.
After the screen data has been cleared, if an attempt is made to set the
NT31/NT31C to the RUN mode before screen data has been transmitted from the
Support Tool or memory unit, an error message will be displayed and the RUN
mode will not be established.
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...