![Omron NT31 Series Скачать руководство пользователя страница 602](http://html1.mh-extra.com/html/omron/nt31-series/nt31-series_operation-manuals_744552602.webp)
591
Commands/Responses
Section 9-3
9-3-17
Character string input notify command
(Sent from PT to host)
Command
[Format]
1B
53
[ESC]
S
t3
d11
53
S
t1
d12
t2
0D
t4
dn1
dn2
s1
s2
[CR]
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
t
1
to t
4
:
Input character string memory table number (4 BCD digits)
0000 to 0499
This is the number of the character string memory table for which
there has been character string input.
d1
1
, d1
2
, ..., dn
1
, dn
2
:
Input character string data (1 to 40 characters)
00 to FF
H
In the case of character string memory tables allocated to the
host, this is the registered number of words multiplied by 2, and
the case of character string memory tables not allocated to the
host, it is data for 40 characters.
s
1
, s
2
:
Check sum (2 hexadecimal digits)
This is always added.
Response
[Format]
None
[Function]
S
In accordance with operations at the PT, such as character string settings and
copying of character string memory tables, notifies the host that a character
string has been input to the character string memory tables.
Example
S
Command
0
1B
53
[ESC]
S
31
4F
30
0
53
S
2
32
30
1
4F
0D
4E
30
46
0
F
[CR]
4D
52
O
M
R
O
N
Input character string memory table number : No.210
Input character string data (hexadecimal)
: OMRON
Check sum (hexadecimal)
: 0FH
Here, it is ascertained that “OMRON” has been input to character string memory
table No.210.
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...