641
Specifications
APPENDIX A
External Interface Specifications
Item
Specification
Serial communication
Serial port A
Conforms to EIA RS-232C
D-SUB 9-pin connector (female)
+5 V (250 mA max.) output at pin No. 6
Serial communication
Serial port B
EIA RS-232C or RS-422A/485 (selectable, by memory switch setting)
D-SUB 25-pin connector (female)
Parallel interface
Conforms to Centronics standard, 20-pin half pitch connector
Expansion interface
Dedicated connector
Notice
Check that the current capacity of the equipment to be supplied is within 250 mA
before using the +5 V output of pin No. 6.
The +5 V output of the unit de5 V
"
5% and 250 mA maximum.
Programming environment
Item
Specification
Programming System
Programming support software
Programming Tool
Programming support software
NT-series Support Tool for Windows 95/98 (Ver. 3.0), made by OMRON
Personal Computer
Use a personal computer which can run Microsoft Window 95 or 98
RAM : At least 32 M bytes
Fore Area in bord disk : At least 25 M bytes (To install sample colection, more 12 MB is required)
Input device : Keyboard, mouse
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...