113
Connecting to the Host’s RS-422A/485 Port
Section 5-2
5-2
Connecting to the Host’s RS-422A/485 Port
The methods for connecting the RS-422A/485 port of the NT31/NT31C and the
RS-422A/485 port of the host are described here. There are the following meth-
ods.
The following discussion is focused on the connection method to OMRON PCs
(By using the memory link method, a connection can be made to any arbitrary
RS-422 unit). When making a connection to a host other than OMRON PCs, refer
to the “ PC Connection” (V042-E1-
).
Method in which the RS-422A ports of the NT31/NT31C and host are connected
directly by an RS-422A cable (page 133).
When this method is used, the cable length can be extended up to 500 m.
PT
Host
RS-422A cable
(max. 500 m)
Method in which the RS-485 ports of the NT31/NT31C and host are connected
by an RS-485 cable (page 138).
When this method is used, the cable length can be extended up to 500 m.
This connection method canbe used only with the NT link (1:N) method of type
RS-485.
PT
Host
RS-485 cable
(max. 500 m)
Method in which the RS-422A ports of multiple NT31/NT31Cs and the RS-422A
port of the host are connected in a 1:N connection (page 139).
This connection method is used with the RS-422A type NT link (1:N) method.
PT
Host
RS-422A cable
(max. total length 500 m)
Method in which the RS-485 ports of multiple NT31/NT31Cs and the RS-485
port of the host are connected in a 1:N connection (page 142).
This connection method is used with the with the RS-485 type NT link (1:N)
method.
PT
Host
RS-485 cable
(max. total length 500 m)
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...