![Omron NT31 Series Скачать руководство пользователя страница 343](http://html1.mh-extra.com/html/omron/nt31-series/nt31-series_operation-manuals_744552343.webp)
332
Lamps
Section 7-6
Light Function
Address
PC Bit Address
Allocated bit of the lamp (“Allocated bit”, page 332)
I/O Comments
Comment that indicates the contents of the allocated bit
Up to 16 alphanumeric characters
ON state
Position
OFF state
Position
- Allocated bit
Lamp bits can be allocated to the following host (PC) areas.
Symbol
C Series PLC
Alloca
tion
CVM1/CV
Series PLC
Alloca
tion
CS1 Series PLC
Alloca
tion
DM
Data memory
✓
Data memory
✓
Data memory
✓
CH
I/O relay
✓
I/O relay
✓
I/O relay
✓
TIM
Timer present
value
×
Timer present
value
×
Timer present
value
×
CNT
Counter present
value
×
Counter present
value
×
Counter present
value
×
HR
Holding relay
✓
#
#
Holding relay
×
AR
Auxiliary relay
✓
Special
auxiliary relay
×
Special
auxiliary relay
×
LR
Link relay
✓
#
#
#
#
EM
Expansion data
memory *1 *2
✓
Expansion data
memory *2
EM current
Bank *2
✓
✓
: OK
×
: NG
: Host link NG
*1 C--series EM (Expansion Memory) is available only in the C200HX/HG/HE (-Z).
*2 The EM (Expansion Memory) can be alocated only in the current bank.
Since the special auxiliary relays of the CVM1/CV series PCs are all allocated
to system functions, they cannot be used for purposes other than system use.
The range of each memory area differs according to the PC type. Refer to
APPENDIX L “PC Memory Map”, page 684.
[Input Functions]
Lamps read the contents of a bit at the host and execute processing in accordance
with the bit status.
However, the bit is only read in the following case:
S
When a lamp is used on the currently displayed screen
[Output Functions]
Lamps have no output function.
[Processing Functions]
Lamps have no data processing function.
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...