Using an RS-232C/RS-422A Convertor Unit
APPENDIX C
Mounting to a DIN Rail
Latch the top part of the rear face of the convertor unit (“a” in the figure) onto the top edge of the DIN rail, and push
the unit in the direction indicated by “b” in the figure.
Now fit end plates at the right and left of the convertor unit to secure it and ensure that it cannot shift laterally.
(b)
(a)
Removal from a DIN Rail
Remove the end plates at right and left of the convertor unit and, as shown in the figure below, insert a flat blade
screwdriver into the rail stopper at the bottom face of the convertor unit and prize it free.
Mounting to an Operation Panel
Drill two mounting screw holes in an operation panel with a thickness of at least 2 mm (0.08 inch) and secure the
convertor unit with screws.
(1.18)
30
21
100
(3.94)
110
(4.33)
2-M4
Units: mm (inch)
(0.83)
Note
In order to ensure a secure and strong mount, mount the convertor unit in an op-
eration panel with a thickness of at least 2 mm (0.08 inch).
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...