Areas for Control/Notification
Section 7-2
2
Set the type of the memory table to be copied for “memory table copy type” (bit
2) of the PT status control bits (word n + 3) as follows.
@
1 (ON):
When copying between numeral memory tables
@
0 (OFF): When copying between character string memory tables
3
Set “1” (ON) for “memory table copy execution” (bit 3) of the PT status control
bits (word n + 3).
The memory table data is copied.
4
After copying has been executed, return “memory table copy execution” (bit 3)
to “0”.
Reference
- If the display method or number of registered words is different for the copy
source and copy destination memory tables, the data may not be displayed cor-
rectly.
- If the contents of memory tables are changed by PT status control area opera-
tion, the change in memory table contents is not notified by the PT status notify
area.
- Alarm history initialization (bit 1)
This bit is used to initialize the alarm history recorded in the NT31/NT31C.
When it is switched from “0” (OFF) to “1” (ON), the alarm history in the
NT31/NT31C is initialized.
After initialization, return its status to “0”.
Reference: The alarm history can also be initialized from the “MEMORY INIT. MENU” screen
under the System Menu of the NT31/NT31C.
7-2-2
PT Status Notify Area (NT31/NT31C to Host)
The PT status notify area is provided to notify the host of changes in the status of
the NT31/NT31C. The host can determine the status of the NT31/NT31C by read-
ing this area.
The PT status notify area is configured as two consecutive words as shown below.
The first word (word m) is set in the “Control/Notify Area” settings in the PT config-
uration settings made with the Support Tool.
Word
0
0
0
m + 1
PT status
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0 Bit
Numeral/character string memory table number
(4-digit BCD or hexadecimal value)
Content update
memory table
PT status notify bits
m
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...