590
Commands/Responses
Section 9-3
Response
[Format]
None
[Function]
S
In accordance with operations at the PT, such as numeral setting and copying of
memory tables, notifies the host that a numeric value has been input to the nu-
meral memory table.
S
Since it is not possible to write to numeral memory tables from No.247 to No253
(areas for clock data display/reading use only), notification of these tables is not
executed.
Example
S
Command
t1
1B
53
[ESC]
S
d4
t4
4E
N
t2
t3
0D
d1
d2
d3
d8
d5
d6
d7
s1
s2
[CR]
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
* *
Input numeral memory table number
: No.150
Input numeric value data (hexadecimal)
: 30000H
Check sum (hexadecimal)
: 05H
Here, it is ascertained that 30000 has been input to numeral memory table No.150
(whether this is 30000 in hexadecimal or 30000 in BCD is determined by the nu-
meral storage type set for the numeral memory table).
00196608
00030000
00030000
00030000
Input numeral
Numeral memory table No. 150
BCD
Binary
Содержание NT31 Series
Страница 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Страница 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Страница 41: ...30 Before Operating Section 1 5...
Страница 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Страница 160: ...149...
Страница 174: ...163...
Страница 193: ...182...
Страница 211: ...200...
Страница 235: ...224 c Return to the screen on which screens are specified...
Страница 262: ...251...
Страница 284: ...273 The printer type control protocol and printing method are set with the memory switches of the NT31 NT31C...
Страница 347: ...336 Screen number 5 is set for touch switch 1 To next screen When touch switch 1 is pressed Screen number 5...
Страница 360: ...349 It is not possible to control a gloval window by touch switch operation...
Страница 375: ...364 For details on the method of display depending on the General settings refer to Common Attributes page 358...
Страница 391: ...380 1 The 100 value 0 value and 100 value must comply with the following relationship 100 value 0 value 100 value...
Страница 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Страница 476: ...465 Special Functions Section 7 16...
Страница 495: ...484 OFF...
Страница 610: ...599 Commands Responses Section 9 3...
Страница 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...