Appendix A
Data Conversion
477
Difference
New models:
Control touch switches are annexed to alarm lists/his-
tories; correction is possible only with regard to the
position of the touch switches.
When converted to the NT21, NT31/631-V2 or later
models (NT20/30/620-compatible mode ON)
associated touch switches will keep other properties,
as it is, only thing is that it cannot be edited separately.
Conventional models: Control touch switches can be handled as indepen-
dent touch switches (to be associated with alarm lists/
histories). Their position, size, label, etc. can be
edited as desired.
Switches:
When converted to the NT21, NT31/631-V2 models
(20/30/620 mode on) associated touch switches will
keep other properties, as it is, only thing is that it can-
not be edited separately.
Conversion result, error message and corrective action
Status before
Conversion
Status after
Conversion
Error Message
Corrective Action
With a conventional
model, an alarm list/
history is registered
for a screen and
touch switches are
associated with it.
With a new model,
the associated
touch switches are
deleted and the
control touch
switches (in the ini-
tial state) are auto-
matically created.
When converted to
the NT21,
NT31/631-V2 or lat-
er models
(NT20/30/620-com-
patible mode on)
associated touch
switches will be
converted to control
touch switches, oth-
er properties re-
maining the same.
[E]
Touch Switch func-
tion type is not sup-
ported. It is dis-
carded.
[W]
The associated
touch switches of
the alarm has been
discarded and com-
ponent touch
switches have been
created.
No error message
will be generated.
Adjust the position of
control touch switches if
necessary. (Refer to
6-3
Alarm
.)
With a conventional
model, an alarm list/
history is registered
for a screen (with-
out control touch
switches).
With a new model,
control touch
switches (in the ini-
tial state) are auto-
matically created.
[W]
The associated
touch switches of
the alarm has been
discarded and com-
ponent touch
switches have been
created.
If control touch switches
are not necessary, de-
lete them by setting in
the alarm list/history
properties. (Refer to
6-3
Alarm
.)
With a new model,
touch switches are
automatically
created by register-
ing alarm list/history
to the symbol man-
ager.
With a conventional
model, all control
touch switches are
deleted.
[W]
The component
Touch Switches of
the Alarm List will
be discarded.
Create the control touch
switches using the touch
switch control code input
function and associate
them with the alarm list/
history. (Refer to
6-8-5
Control Code Input
Touch Switches
.)
Correction of touch switch position and size
Touch switch size differs between NT20, NT20S, NT600S, NT620S and other PT
models.
Therefore, when the data of NT20, NT20S, NT600S, NT620S is converted to the
data for other PT models, touch switch position and size may change.
Содержание NT-SERIES - SUPPORT TOOL FOR WINDOWS V4
Страница 1: ...Cat No V061 E1 06 Support Tool for Windows Ver 4 NT Series OPERATION MANUAL...
Страница 2: ......
Страница 3: ...NT series Support Tool for Windows Ver 4 j Operation Manual Revised July 2010...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 14: ......
Страница 80: ......
Страница 94: ......
Страница 338: ......
Страница 359: ...8 2 Section Library Editor 343 Double clicking the control menu box of the library editor Control menu box...
Страница 422: ......
Страница 458: ......
Страница 478: ......
Страница 502: ......
Страница 508: ......
Страница 532: ......
Страница 556: ......
Страница 560: ......
Страница 562: ......
Страница 564: ......
Страница 570: ......
Страница 572: ......
Страница 584: ......
Страница 590: ......
Страница 592: ......
Страница 593: ......