Any of the bits assigned to a flag indicate that an error exists when it is ON. The
meanings of the various flags are described in the table below.
Memory error
Not set.
Not set.
Not set.
Sensor AD error
Current Transformer AD error
Cold junction compensation error
Not set.
@
0
Unit R
U
End
code
CR
Header code
FCS
Terminator
*
Status
7
6
5
4
3
2
1
0
15 14
13
12
11
10
9
8
Not set.
Not set.
Not set.
Not set.
Not set.
Not set.
Not set.
Parameter Error
Bit no.
Bit status: 1: error; 0: normal
Name
Meaning
Memory Error flag
This error occurs when the contents of the memory have been destroyed, the CPU
goes out of control, or when power is turned off before the response is received to the
EEPROM Write command. Turn the E5ZD off and then on again. If recovery is not
possible by initializing both RAM (with the Initialize Parameters command), and then
EEPROM (with the EEPROM Write command), E5ZD calibrations may have been
destroyed.
Sensor AD Error flag
The sensor AD converter circuitry may have failed. Turn the E5ZD off and on.
Current Transformer AD Error
flag
The Current Transformer AD converter circuitry may have failed. Turn E5ZD power off
and on.
Cold Junction Compensation
Error flag
This error is generated when CN3 has been disconnected or the ambient temperature
of the E5ZD has dropped below –15
°
C or exceeded 60
°
C. For the E5ZD-8
jj
KJ-E it
is generated when CN903 is not connected correctly, and for the E5ZD-8H
j
KJM-E it
is generated when the two terminal blocks for thermocouple input are disconnected.
Parameter Error flag
This error is generated when parameters in memory have been destroyed or parame-
ters that do not agree with switch settings have been written into memory. Reinitialize
memory with the Initialize Parameters command. The error may also be generated if
°
C is changed to
°
F or vice versa.
Response Examples
This response shows a memory error for Unit 0.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
@ 0
0
R
U
0
0
0
0
0
1
4
6
CR
*
Memory error
End Codes
If an end code of 00 was returned in the response, the command was executed
normally. If the end code is not 00, the desired data will not have been read. Re-
Temperature Control Commands (All Controllers)
Section 4-2
Содержание E5ZD
Страница 1: ...Cat No Z042 E1 4 Multipoint Temperature Controller E5ZD ...
Страница 2: ......
Страница 3: ...E5ZD Multipoint Temperature Controller Operation Manual Revised November 1996 ...
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 8: ......
Страница 10: ......
Страница 18: ......
Страница 76: ......
Страница 128: ......
Страница 132: ......
Страница 142: ......
Страница 146: ......
Страница 148: ......
Страница 150: ......
Страница 154: ......
Страница 157: ...Cat No Z042 E1 4 E5ZD Multipoint Temperature Controller OPERATION MANUAL ...