114
Header
Code
Operation
Data
Code
Point
Memory
Bank
RU
0
0
00
Reads output modes.
01
Do not use (0000).
02
Reads points set for HB and HS alarms.
03
Reads error status.
AA
Reads output modes, points set for HB and HS alarms, and error status.
RV
0 to 7
0 to 7
00
Reads derivative time as specified.
A
00
Reads derivative times for all points.
A
0 to 7
00
Reads derivative times for all banks.
RW
0
0 to 7
00
Reads heater burnout detection level as specified.
A
00
Reads heater burnout detection level for all points.
RX
0
0 to 7
00
Reads measured temperature as specified.
01
Reads output percentage as specified.
02
Reads operating status as specified.
AA
Reads measured temperature, output percentage, and operating status.
A
00
Reads measured temperatures for all points.
01
Reads output percentages for all points.
02
Reads operating status for all points.
RZ
0
0 to 7
00
Reads heater current as specified.
A
00
Reads heater currents for all points.
Rj
0 to 7
0 to 7
00
Reads fuzzy strength as specified.
A
00
Reads fuzzy strength for all points.
Rk
0 to 7
0 to 7
00
Reads fuzzy scale 1 as specified.
A
00
Reads fuzzy scale 1 for all points.
Rl
0 to 7
0 to 7
00
Reads fuzzy scale 2 as specified.
A
00
Reads fuzzy scale 2 for all points.
4-5 Global Write Operations
Special designations can be used for the memory bank, control point, and data
code designations to allow certain commands to write the same data into the
same parameter for all control points, all memory banks for a specified control
point, or/and all data codes with the same header code. The commands for glob-
al write operations are listed in the table at the end of this section.
Command Format
The format for this command is as shown below. The unit number, header code,
memory bank, control point, and data code must be identified with a special des-
ignation specifies the groups to be acted on: i.e., memory bank, control point,
and/or data code.
If “A” is used for the control point, all of the control points for the specified Unit are
specified; if “A” is used for the memory bank, all of the memory banks for the spe-
cified control point are specified; if “AA” is used for the data code, all possible
data codes with the specified header code are specified.
Global Write Operations
Section 4-5
Содержание E5ZD
Страница 1: ...Cat No Z042 E1 4 Multipoint Temperature Controller E5ZD ...
Страница 2: ......
Страница 3: ...E5ZD Multipoint Temperature Controller Operation Manual Revised November 1996 ...
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 8: ......
Страница 10: ......
Страница 18: ......
Страница 76: ......
Страница 128: ......
Страница 132: ......
Страница 142: ......
Страница 146: ......
Страница 148: ......
Страница 150: ......
Страница 154: ......
Страница 157: ...Cat No Z042 E1 4 E5ZD Multipoint Temperature Controller OPERATION MANUAL ...