OMRON
PART 1: CX-Programmer
CX-Programmer_Page (v)
Enhanced User Interface for Menu and Option Settings
Previous version (version 8.3)
New version (version 9.0)
The display configuration for menus and options
cannot be changed.
Switching to Smart Style Mode is now possible
for the menu and option setting style.
Smart Style is the same type of menu and option
setting function as the one supported in CX-
Programmer for CP1E.
Either the previous Classic Mode or the new
Smart Style Mode can be selected for the menus
and options by selecting
Tools - Options
and
then setting the
Menu/Options Style
on the
General Tab Page.
Changes to Search/Replace Dialog Boxes
Previous version (version 8.3)
New version (version 9.0)
Searches can be performed only in the entire
PLC or in the data in the current view.
"Programs" has been added to the search range.
The setting for the item to be searched for was
very detailed and included bit addresses,
address, values (constants/numbers),
mnemonics, symbols, and I/O comments.
Searched objects have been grouped into
addresses, symbol names, and all (text strings).
Replacements can be performed only in the
entire PLC or in the data in the current view.
"Programs" has been added to the replacement
range.
Also, the selected circuits can be set as the
replacement range.
The setting for the item to be replaced was very
detailed and included bit addresses, address,
values (constants/numbers), mnemonics,
symbols, and I/O comments.
Searched objects have been grouped into
addresses, symbol names, mnemonics, and
comments.
Version 8.3 Upgrade Information
Functionality Improved from Version 8.2 to 8.3
Compatible PLC Models
The functionality improvements are supported for CJ2H CPU Units with unit version
1.2 or later.
TIMER and COUNTER Added as Symbol Data Types
Previous version (version 8.2)
New version (version 8.3)
When defining timer numbers and counter
numbers as symbols, the following three different
symbols had to be registered in the symbols
table.
1.
Timer numbers and counter numbers
specified in instruction operands had to
be defined as NUMBER symbols.
2.
Timer and Counter Completion Flags
had to be defined as BOOL symbols.
3.
Timer and counter present values had
to be defined as CHANNEL symbols.
TIMER and COUNTER symbols are supported
so that all of the previous three types of symbols
can be managed as one data type. (TIMER and
COUNTER are supported only by CJ2H CPU
Units with unit version 1.0 or later.)
TIMER: Can be used for 1) the timer number, 2)
the Timer Completion Flag, and 3) the timer
present value.
COUNTER: Can be used for 1) the counter
number, 2) the Counter Completion Flag, and 3)
the counter present value.
Automatically assigning timer and counter
numbers in ladder programs was not possible.
Automatic address assignment and layout are
supported for TIMER and COUNTER symbols.
(TIMER and COUNTER are supported only by
CJ2H CPU Units with unit version 1.0 or later.)
Содержание CX-PROGRAMMER V9
Страница 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 33: ...PART 1 CX Programmer...
Страница 34: ......
Страница 91: ......
Страница 111: ......
Страница 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Страница 217: ......
Страница 233: ......
Страница 234: ...PART 2 CX Server PLC Tools...
Страница 235: ......
Страница 243: ......
Страница 249: ......
Страница 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 280: ......
Страница 333: ......
Страница 377: ......
Страница 409: ......
Страница 430: ......
Страница 431: ...PART 3 CX Server Runtime...
Страница 432: ......
Страница 476: ......
Страница 482: ......
Страница 498: ......
Страница 524: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......