PART 1: CX-Programmer
OMRON
CHAPTER 4 – Reference
CX-Programmer _Page 99
Canceling the Program Transfer
While transferring a program to or from a PLC it is possible to cancel the transfer by clicking the
Cancel
button.
However depending on when the button is pressed different functionality will occur.
If the
Cancel
button is pressed before or during the Memory Clear phase the memory clear will be completed
but the data transfer will not take place. If the button is pressed during the Transfer phase the transfer will be
stopped and the PLC memory will be cleared. The transfer will not be completed.
Comparing Programs
The project PLC program data can be compared with the data inside the PLC.
The following comparisons may be performed, depending on PLC type:
♦
Program step number and instructions;
♦
PLC data;
♦
Expansion Instruction Table (CQM1, C200HE, C200HG, C200HS and C200HX only);
♦
UM allocation data (CQM1, C200HE, C200HG, C200HS and C200HX only).
Use the following procedure to compare programs on the computer and on the PLC.
1, 2, 3…
1. Select the PLC object in the project workspace.
2. Select
the
Work On-line
button from the toolbar. A confirmation message is displayed;
select the
Yes
pushbutton to connect to the PLC.
3. Select
the
Compare with PLC
button from the toolbar. The
Compare Options
dialog is
displayed allowing comparisons of programs, settings and IO table individually or
together.
4. Set the settings as required and select the
OK
pushbutton. The items that can be
downloaded vary according to PLC series.
Details regarding comparisons between computer and PLC programs are displayed in the Compare Result dialog
box.
The results of verification can be saved to a file in CSV format.
Two methods can be used to display the comparison results.
•
Overview display: Program lists are displayed of the compare programs.
•
Mnemonic display: The specified program is displayed in mnemonic form with differences displayed in color.
The comparison results are displayed by section and mnemonic, including added instructions. You can also
jump from the mnemonic comparison results to the corresponding position in ladder view. The comparison
results can be saved in a file by selecting
Save As
from the
File
menu in the
Compare Result
dialog box. If the
file is saved from the overview display, the comparison results for all programs will be saved in CSV format. If
the file is saved from the mnemonic display, the comparison results for the currently displayed program will be
saved in CSV format.
The following abbreviations will be displayed between program addresses and mnemonics and will be in the
CSV file.
*: Mismatch, D: Difference, M: Moved, N: Missing
Transferring Programs, Symbols, Comments and Index to and from File/File-card
It is possible to write a combination of program code, program comments and symbol definitions to a set of
files. It is possible to read these files back.
If a file-card can be attached directly to the computer (via a PCMCIA controller, for example), then it can be
used as a disk device like a floppy drive, and files may be directly transferred with it.
1, 2, 3…
1. Select the PLC object in the project workspace.
2. Select
the
Transfer/To File
or
Transfer/From File
options from the PLC menu. Or
select
Load Comment/Program
or
Save Comment/Program
options from the File
menu. A dialog is presented which allows the filename to be set or browsed. Choose
whether to include
Programs
,
Comments
,
Symbols
or
Index
in the transfer on this
dialog.
For programs, a short
Comment
may also be given for inclusion in the file.
Содержание CX-PROGRAMMER V9
Страница 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 33: ...PART 1 CX Programmer...
Страница 34: ......
Страница 91: ......
Страница 111: ......
Страница 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Страница 217: ......
Страница 233: ......
Страница 234: ...PART 2 CX Server PLC Tools...
Страница 235: ......
Страница 243: ......
Страница 249: ......
Страница 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 280: ......
Страница 333: ......
Страница 377: ......
Страница 409: ......
Страница 430: ......
Страница 431: ...PART 3 CX Server Runtime...
Страница 432: ......
Страница 476: ......
Страница 482: ......
Страница 498: ......
Страница 524: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......