PART 2: CX-Server PLC Tools
OMRON
CHAPTER 2 – PLC Memory Component
CX-Server PLC Tools_ Page 15
specified bank and all banks following it. This is called the EM Area force-setting/resetting
function.
Use the following procedure.
1. Select
Memory Allocate
−
EM Memory Settings
from the PLC Menu. The following
EM Memory Settings Dialog Box will be displayed. Select the
Enables the Force
On/Off setting of EM banks
Check Box in the EM Force On/Off Area, select the
starting back from the pull-down menu in the
EM Start File No.
Box, and then click
the
OK
Button.
2.
Go online with the CPU Unit, select
Transfer – Transfer to PLC
from the PLC Menu,
and transfer the program to the CPU Unit.
Note:
With CJ2H CPU Units with unit version 1.0 or 1.1, force-setting/resetting bits
in the EM Area is supported only for areas specified for automatic address
assignment. With CJ2H CPU Units with unit version 1.2 or later,
force-setting/resetting bits in the EM Area is supported both for areas
specified for automatic address assignment and for the EM Area
force-setting/resetting function described above.
PLC Memory Management
A number of features of the PLC Memory Component are common to both the
Memory
tab and
Address
tab.
PLC Memory component files can be saved to the CX-Server project. Use the following procedure to save PLC
Memory component details to the CX-Server project.
1, 2, 3…
1. Select
the
Save in Project
button from the toolbar. The Save dialog is displayed.
2. Select the required data areas to include in the file from the
Areas to Save:
field.
3. Enter a comment in the
File Comment
field.
4. Select
the
OK
pushbutton to proceed.
PLC Memory component files can be saved via a standard File Save dialog. Use the following procedure to save
a PLC Memory component file.
1, 2, 3…
1. Select
Save to File
from the
File
menu. The Save dialog is displayed.
2. The Save dialog is displayed. Select the required data areas to include in the file from the
Areas to Save:
field.
3. Enter a comment in the
File Comment
field.
4. Select
the
OK
pushbutton to proceed.
5. A standard File Save dialog is displayed. Enter a file name in the
File name
field and select
the
Save
pushbutton. PLC Memory files have a .MEM extension.
Information saved to a file can be supplemented with header information set as a preference. Refer to
Chapter 2 -
PLC Memory Component
for details of setting header information to a file.
PLC Memory component files can be retrieved via a standard File Open dialog. Use the following procedure to
open a PLC Memory component file.
1, 2, 3…
1. Select
the
Open File
button from the toolbar to open a PLC Memory component file. A
confirmation message box may appear if the file is already open. Select the
Yes
pushbutton
to save the currently open details. Select the
No
pushbutton to discard the currently open
details. Select the
Cancel
pushbutton to abort the operation.
2. A standard File Open dialog is displayed. Select a file from the Open PLC Memory File
dialog, followed by the
Open
pushbutton. PLC Memory files have a .MEM extension.
PLC Memory component data can be printed. Use the following procedure to print details.
1, 2, 3…
1. Open the Address Monitor window from the
Address
tab or a data area window from the
Memory
tab.
2. Select
the
Print Preview
button from the toolbar. A preview window is displayed.
Содержание CX-PROGRAMMER V9
Страница 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 33: ...PART 1 CX Programmer...
Страница 34: ......
Страница 91: ......
Страница 111: ......
Страница 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Страница 217: ......
Страница 233: ......
Страница 234: ...PART 2 CX Server PLC Tools...
Страница 235: ......
Страница 243: ......
Страница 249: ......
Страница 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 280: ......
Страница 333: ......
Страница 377: ......
Страница 409: ......
Страница 430: ......
Страница 431: ...PART 3 CX Server Runtime...
Страница 432: ......
Страница 476: ......
Страница 482: ......
Страница 498: ......
Страница 524: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......