PART 2: CX-Server PLC Tools
OMRON
CHAPTER 3 – IO Table Component
CX-Server PLC Tools_ Page 31
3. Click on the
Insert
pushbutton.
4. Enter the IP Address for the node in the
IP Address
field; each of the four fields must take
a value in the range 0 to 255.
5. Select
the
OK
pushbutton to proceed.
6. Click on the
Delete
pushbutton to remove the address from the table.
7. Select
Transfer from PLC
from the
Options
menu to write the changes back to the table.
The IP Router Table establishes communications between different networks by maintaining the IP address for
each interface and is created by clicking on the
Insert
pushbutton above the IP Router table dialog. Procedures are
the same as for the IP Address Table described above.
Syslink Unit and Controller Link Specific Settings
A Syslink unit Software Switches dialog includes a
General
tab and
Data Link
tab described previously.
The
Error Information
tab provides read-only information regarding the errors that the PLC can detect and raise
an error flag.
The
Network Status
tab provides network status information. It also activates the PLC to perform internode tests.
Select the
Start
option to set the PLC to check for errors and report them. Select the
Stop
option to stop the PLC
from detecting errors. The
Network Node List
field lists the network nodes and whether they are participating in
the network operations.
Sysmac-Bus2 Unit Specific Settings
A Sysmac-Bus2 unit Software Switches dialog includes a
General
tab described previously.
The
Slave
tab provides specific status information to the Sysmac-Bus2 unit. There are various types of slave that
may be connected to a Remote IO Master unit. These slaves include IO Terminals, Programmable Displays and
Remote IO Slave units.
To view the slaves connected for a group, select the Group required from the field at the top of the
Slaves
tab. The
remainder of the
Slaves
tab displays the Node and Status for each category.
If the hierarchy of the IO Table has been expanded, the three groups can be populated with other units:
♦
Group 1. 16-point and 32-point IO units.
♦
Group 2. 16-point, 32-point, 64-point and 128-point IO units and 256-point dummy.
♦
Group 3. 58M Remote Terminal, 54MH Remote Terminal and 122M Remote Terminal.
Serial Communications Unit Specific Settings
Serial Communications unit specific software switches settings can only be set for CS/CJ/CP series PLCs.
A Serial Communications unit Software Switches dialog includes a
General
tab described previously.
The
Port 1
tab and
Port 2
tab are identical. Settings can be specified for the
Format
field,
Mode
field and
Hardware
field.
Displaying Unit Error Log in the IO Table
By selecting a CPU Bus Unit or Special IO Unit in the IO table tree and clicking the right mouse button to select
the Unit Error Log Menu, the error log for the selected Unit can be displayed (CX-Programmer Ver. 4.0 or later).
IO Table Management
Changes made to an IO Table can be done by simply editing particular fields in the table. Basic information can be
changed by displaying the configuration, selecting the rack or unit that needs to be changed and editing or
selecting the new IO address or configuration information.
All slot allocations in the IO Table can be cleared. Select
Clear
from the
Options
menu.
An IO Table unit in the PLC’s Registered IO Table in the PLC can be deleted. Use the following procedure to
delete an IO Table Unit.
Содержание CX-PROGRAMMER V9
Страница 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 33: ...PART 1 CX Programmer...
Страница 34: ......
Страница 91: ......
Страница 111: ......
Страница 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Страница 217: ......
Страница 233: ......
Страница 234: ...PART 2 CX Server PLC Tools...
Страница 235: ......
Страница 243: ......
Страница 249: ......
Страница 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 280: ......
Страница 333: ......
Страница 377: ......
Страница 409: ......
Страница 430: ......
Страница 431: ...PART 3 CX Server Runtime...
Страница 432: ......
Страница 476: ......
Страница 482: ......
Страница 498: ......
Страница 524: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......