PART 2: CX-Server PLC Tools
OMRON
CHAPTER 4 – PLC Setup Component
CX-Server PLC Tools_ Page 45
Address Enable
The
Address Enable
tab of the PLC Setup component allows addresses to be entered for selected local racks.
Some of the options may not be applicable depending on the device type selected. Use the following procedure to
apply settings in the
Address Enable
tab.
1, 2, 3…
1. Enter an address for each required
Local rack
setting. The first word can be set between 0
and 511. Word allocations must not overlap. The default for the CPU rack is zero. If word
allocations overlap, they are ignored and the address returns to zero. Racks selected
without a designated first word is allocated words automatically beginning from CIO 0000.
2. Enter
the
Group 1
and
Group 2
values. This is the first word between CIO 0000 and CIO
0999 for each SYSMAC BUS/2 Group 1 and 2 Masters.
3. Enter
the
Group 3
values. These are the first word for each SYSMAC BUS/2 Group 3
Slave between CIO 0000 and CIO 0999 for each SYSMAC BUS/2 Group 1 and 2 Masters
and the first word for each SYSMAC BUS/2 Slave rack between CIO 0000 and CIO 2555.
4. Enter
the
RT Terminals
,
SIOU
and
IO terminals
addresses as required.
Note:
Each group (Group 1, 2 and 3) has pre-set values assigned as a default. Group 1 and
Group 2 supports 32 and 16 IO units respectively. Group 3 is reserved for racks and
supports eight racks, each of which supports eleven slots.
PLC Timings
The
PLC Timings
tab of the PLC Setup component allows cycle, interrupt and event times to be set. Use the
following procedure to apply settings in the
PLC Timings
tab.
1, 2, 3…
1. Check
the
Watch Cycle Time
setting and set the watch cycle time if enabled for the PLC;
the default is 1000 ms.
2. Check
the
Power Off Interrupt
setting, and set if enabled for the PLC; the default is 0 ms.
3. Set
the
Cycle Time
setting to define the time interval for cycles.
4. Set
the
Scheduled Interrupt Interval
setting to schedule interrupts to occur at regular
intervals; either every 10 ms or a specific value can be set.
Hold
The
Hold
tab of the PLC Setup component allows the Hold area of the PLC’s Work Area memory to be defined.
Use the following procedure to apply settings in the
Hold
tab.
1, 2, 3…
1. Check
the
Enable Hold Area
setting to enable the Hold area and select its
Start
and
End
Address
settings.
2. Check the required racks from the
CPU
field.
3. Check the required Sysbus/2 remote master from the
Sysbus/2 Remote Master
field.
4. Check the required Sysbus remote master from the
Sysbus Remote Master
field.
C-Series PLC Settings
The following paragraphs describe the features of the PLC Setup component associated with C-series PLCs. Refer
to
Chapter 4 - PC to PLC Communications
for details of transferring PLC setup information to and from the PLC.
The common
Set Default
option resets PLC Setup component values to the default settings.
PLC Startup
The
PLC Startup
tab of the PLC Setup component allows certain PLC settings to be made which always take
effect on startup (until they are explicitly altered). Use the following procedure to apply settings in the
PLC
Startup
tab.
Mode
This option selects the default PLC operation mode when the PLC is powered on.
1, 2, 3…
1.
Program
– Select this for online programming when the PLC is powered on.
2.
Monitor
– Select this to start monitoring the running program when the PLC is powered on.
3. Run
– Select this to run the PLC’s program when the PLC is powered on.
Содержание CX-PROGRAMMER V9
Страница 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 33: ...PART 1 CX Programmer...
Страница 34: ......
Страница 91: ......
Страница 111: ......
Страница 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Страница 217: ......
Страница 233: ......
Страница 234: ...PART 2 CX Server PLC Tools...
Страница 235: ......
Страница 243: ......
Страница 249: ......
Страница 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 280: ......
Страница 333: ......
Страница 377: ......
Страница 409: ......
Страница 430: ......
Страница 431: ...PART 3 CX Server Runtime...
Страница 432: ......
Страница 476: ......
Страница 482: ......
Страница 498: ......
Страница 524: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......