PART 1: CX-Programmer
CHAPTER 3 – Project Reference
OMRON
CX-Programmer _Page 44
SFC
It is possible to set the display settings for the SFC diagram editor.
For details, refer to the
CX-Programmer Operation Manual SFC
(Cat. No. W469).
Magnification
The magnification level (i.e. zoom) of the Diagram view can be adjusted to display more or less information as
required. If the diagram is zoomed out then the font becomes smaller and more diagram elements can be seen.
Use the following procedure to set magnification levels.
1, 2, 3…
1.
Open the Diagram Workspace.
2. Select
the
Zoom In
button or the
Zoom Out
button from the toolbar to change the
Diagram Workspace.
3. Select
the
Zoom to Fit
button to change the size of the program width to the length of
the Diagram view.
Finding and Replacing
CX-Programmer provides facilities for finding references to particular text, and replacing text with other text.
There are also powerful replacement options, such as moving a range of addresses to another starting point. The
Search and Replace functionality consists of two dialogs, depending on which operation is being executed. The
Find dialog is opened from the
EDIT | Find
menu option or the key combination
Ctrl+F
.
The Replace dialog is
opened from the
EDIT | Replace
menu option or by pressing
Ctrl+H
.
It is possible to find and replace text from various places: the project workspace, diagram workspace (ladder or
mnemonic views), a symbol table, and an I/O Comment view.
When using the Find and Replace feature from the project workspace, the operation searches the chosen object,
including any objects within it. For example, when finding text from a program within the project workspace,
the local symbol table for that program is also searched. When beginning a search from the project object itself,
everything within the project is searched.
It is also possible to limit the search to a single program window, symbol table, or I/O Comment view by
beginning the search when the relevant ladder, symbol table, or I/O comment window is active.
When
Change All
is selected from the
Edit
menu option, the Change All dialog to replace
Addresses
within
the PLC will be opened. Enter the
Find what
and
Replace with
text as described in
Using Find and Replace
in
this chapter, the replacement of the text will be applied throughout the entire PLC.
Содержание CX-PROGRAMMER V9
Страница 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 33: ...PART 1 CX Programmer...
Страница 34: ......
Страница 91: ......
Страница 111: ......
Страница 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Страница 217: ......
Страница 233: ......
Страница 234: ...PART 2 CX Server PLC Tools...
Страница 235: ......
Страница 243: ......
Страница 249: ......
Страница 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 280: ......
Страница 333: ......
Страница 377: ......
Страница 409: ......
Страница 430: ......
Страница 431: ...PART 3 CX Server Runtime...
Страница 432: ......
Страница 476: ......
Страница 482: ......
Страница 498: ......
Страница 524: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......