PART 1: CX-Programmer
OMRON
CHAPTER 6 – Converting a C500/C120/C**P Program to CS/CJ/CP/CVM1 Format
CX-Programmer _Page 119
Before conversion
After conversion
C500
/C120
C**P
Example
CS/CJ
Series
Example
CV Series
Example
Remarks
FUN75
FUN75 00 10
SRD
SRD 0000 0010
SRD
SRD 0000 0010
FUN75
is converted to its
corresponding instruction,
SRD
.
FUN76
FUN76 00 #0021 10
MLPX
MLPX 0000 #0021 0010
MLPX
MLPX 0000 #0021 0010
FUN76
is converted to its
corresponding instruction,
MLPX
.
FUN77
FUN77 00 10 #0012
DMPX
DMPX 0000 0010 #0012
DMPX
DMPX 0000 0010 #0012
FUN77
is converted to its
corresponding instruction,
DMPX
.
FUN78
FUN78 00 #0013 10
SDEC
SDEC 0000 #0013 0010
SDEC
SDEC 0000 #0013 0010
FUN78
is converted to its
corresponding instruction,
SDEC
.
FUN79
FUN79 00 05 10
FDIV
FDIV 0000 0005 0010
FDIV
FDIV 0000 0005 0010
FUN79
is converted to its
corresponding instruction,
FDIV
.
FUN80
FUN80 #0010 05 #1010
DISTC
DISTC #10 5 #1010
DIST
DIST #0010 0005 #1010
- For CS/CJ-H PLCs,
FUN80
is converted to its
corresponding instruction,
DISTC
.
- For the CV Series,
FUN80
is converted to its
corresponding instruction,
DIST
.
FUN81
FUN81 10 #10 20
COLLC
COLLC 10 #0010 20
COLL
COLL 0010 #0010 0020
- For CS/CJ-H PLCs,
FUN81
is converted to its
corresponding instruction,
COLLC
.
- For the CV Series,
FUN81
is converted to its
corresponding instruction,
COLL
.
FUN82
FUN82 #6537 #1515 00
MOVBC
MOVBC #6537 #1515 0
MOVB
MOVB #6537 #1515
0000
- For CS/CJ-H PLCs,
FUN82
is converted to its
corresponding instruction,
MOVBC
.
- For the CV Series,
FUN82
is converted to its
corresponding instruction,
MOVB
.
FUN83
FUN83 #0100 #0201 10
MOVD
MOVD #100 #201 10
MOVD
MOVD #0100 #0201
0010
FUN83
is converted to its
corresponding instruction,
MOVD
.
FUN84
FUN84 35 10 20
SFTR
SFTR 35 10 20
SFTR
SFTR 0035 0010 0020
FUN84
is converted to its
corresponding instruction,
SFTR
.
FUN85
FUN85 #1000 40 50
TCMP
TCMP #1000 40 50
TCMP
TCMP #1000 0040 0050
FUN85
is converted to its
corresponding instruction,
TCMP
.
FUN87
FUN87 #0050 10 05
IOWR
IOWR 10 &0050 0005
WRIT
WRIT #0050 0010 0005
- The following message will
appear for CS/CJ-H PLCs:
“CONVERT_WARNING:
The instruction specification
is different. Check the
instructions.” Check the
specifications of CPU Unit
after conversion.
- For CJ/CS-H PLCs,
FUN87
is converted to its
corresponding instruction,
IOWR
.
- For CJ/CS-H PLCs, the
first and second operands
are interchanged.
- For CS/CJ-H PLCs, the
second operand is
converted from BCD data
(#0050) to unsigned
decimal data (&0050).
- For the CV Series,
FUN87
is converted to its
corresponding instruction,
WRIT
.
Содержание CX-PROGRAMMER V9
Страница 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 33: ...PART 1 CX Programmer...
Страница 34: ......
Страница 91: ......
Страница 111: ......
Страница 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Страница 217: ......
Страница 233: ......
Страница 234: ...PART 2 CX Server PLC Tools...
Страница 235: ......
Страница 243: ......
Страница 249: ......
Страница 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 280: ......
Страница 333: ......
Страница 377: ......
Страница 409: ......
Страница 430: ......
Страница 431: ...PART 3 CX Server Runtime...
Страница 432: ......
Страница 476: ......
Страница 482: ......
Страница 498: ......
Страница 524: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......