EN-30
U1-08 Output power in kW
U1-09 Torque reference in % of the motor rated torque
U1-10
Input terminal
status
Shows input ON/OFF status.
U1-11
Output termi-
nal status
Shows output ON/OFF status.
U1-12
Operation sta-
tus
Inverter operating status.
U1-13 Cumulative operation time
U1-20 Frequency reference after soft-starter
U1-34 OPE fault parameter
U1-51 Max Current during acceleration
U1-52 Max Current during deceleration
U1-53 Max Current during Top speed
U1-54 Max Current during leveling speed
U1-55 Number of travels
Fault Trace Data
U2-01 Current fault
U2-02 Last fault
U2-03 Reference frequency at fault
U2-04 Output frequency at fault
U2-05 Output current at fault
U2-06 Motor speed at fault
U2-07 Output voltage reference at fault
U2-08 DC bus voltage at fault
U2-09 Output power at fault
U2-10 Torque reference at fault
U2-11 Input terminal status at fault
U2-12 Output terminal status at fault
Param.
Num.
Name
Description
1: FWD command
(S1) is ON
1: REV command
(S2) is ON
1: Multi input 1
(S3) is ON
1: Multi input 2
(S4) is ON
1: Multi input 3
(S5) is ON
1: Multi input 4
(S6) is ON
1: Multi input 5
(S7) is ON
1: Multi-function
contact output 1
(M1-M2) is ON
1: Multi-function
contact output 2
(M3-M4) is ON
1: Multi-function
contact output 3
(M5-M6) is ON
Not used
(Always 0).
1: Error output
(MA/MB-MC) is
ON
Run
1: Zero speed
1: Reverse
1: Reset signal
input
1: Speed agree
1: Inverter ready
1: Minor fault
1: Major fault
U2-13 Operation status at fault
U2-14 Cumulative operation time at fault
Fault History Data
U3-01
to
U3-04
Last fault to Fourth last fault
U3-05
to
U3-08
Cumulative operation time at fault 1 to 4
U3-09
to
U3-14
Fifth last to tenth last fault
U3-15
to
U3-20
Accumulated time of fifth to tenth fault
* The following errors are not recorded in the error log:
CPF00, 01, 02, 03, UV1, and UV2.
Digital Input Function Selections
3
Multi-step speed reference 1
4
Multi-step speed reference 2
6
Jog frequency command (higher priority than multi-step
speed reference)
F
Not used (Set when a terminal is not used)
14
Fault reset (Reset when turned ON)
20 to
2F
External fault; Input mode: NO contact/NC contact, Detec-
tion mode: Normal/during operation
80
Nominal Speed Selection (d1-09)
81
Intermediate Speed Selection (d1-10)
82
Releveling Speed Selection (d1-13)
83
Leveling Speed Selection (d1-17)
84
Inspection Run Selection (d1-14)
Digital Output Function Selections
0
During run 1 (ON: run command is ON or voltage is being
output)
6
Inverter operation ready; READY: After initialization or no
faults
8
During baseblock (NO contact, ON: during baseblock)
B
Car stuck/undertorque detection 1 NO (NO contact, ON:
Overtorque/undertorque detection)
F
Not used. (Set when the terminal is not used.)
10
Minor fault (ON: Alarm displayed)
17
Car stuck/undertorque detection 1 NC (NC Contact, OFF:
Torque detection)
1A
During reverse run (ON: During reverse run)
40
Brake Release Command
41
Output Contactor Close Command
Param.
Num.
Name
Description
Содержание CIMR-L7
Страница 33: ...EN 31...
Страница 65: ...DE 31...
Страница 97: ...ES 31...
Страница 129: ...FR 31...
Страница 161: ...IT 31...
Страница 193: ...PT 31...
Страница 195: ...RU 1 Varispeed L7 5 LC RC...
Страница 198: ...RU 4 2 Omron Yaskawa Motion Control Omron Yaskawa Motion Control 3 20...
Страница 199: ...RU 5 Omron Yaskawa Motion Control 1 IP00 IP20 NEMA 1 2 18 5 22 50 30 30 B 120 B 50 120...
Страница 200: ...RU 6 R L1 S L2 T L3 R S T 600 PE L1 L2 L3 PE GND L1 L2 L3 GND U V W M 3...
Страница 206: ...RU 12 5 V f b1 02 0 H1 xx H2 xx H3 xx C1 xx S C2 x d1 xx C1 xx S C2 xx H1 xx H2 xx d1 18 A1 02 16 17...
Страница 208: ...RU 14 V f E1 E2 E5 F1 01 5 5 T1 01 0 1 2 T1 01 1 1 E2 02 E2 03 T1 01 2 V f 20 T1 01 4 T1 01 V f 0 IM 1 2 4...
Страница 209: ...RU 15 Data Invalid 50 150 27 1 2 3 4 5 BB BB1 6 7 8 9 STOP 1 2 3 4 END 60 2...
Страница 215: ...RU 21 d1 18 2 d1 18 1 H1 83 d1 18 2 H1 83 d1 17 H1 K80 d1 18 2 d1 09 1 2 FRL FRL S3 09 0...
Страница 217: ...RU 23 5 DOWN DOWN n5 05 0 P 1 UP DOWN 2 n5 01 3 n5 05 0 4 5...
Страница 225: ...RU 31...