![OKIDATA ML393C Plus Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/okidata/ml393c-plus/ml393c-plus_service-manual_729925054.webp)
Page: 42
Service Guide ML393/ML393CPlus
Chapter 2 Principles of Operation
2.1.10 Power Supply
This switching power supply converts the AC input voltage to +5 vdc, +/-8 vdc and +38 vdc for use
throughout the printer.
Voltage / Signal Table
Voltage/Signal
Purpose
+5 vdc
IC Logic Levels - LED Drive Voltage
+8 vdc
Serial Interface Logic Levels - Line Feed Motor Locking
Voltage
-8 vdc
Serial Interface Logic Levels
+38 vdc
Printhead Space Motor Line Feed Motor Bail/Ribbon
Motor Drive Voltage
POW ALM
This signal is sent by the Power Supply in the event of
an abnormal temperature rise in the power supply unit or
an overcurrent condition of the +38 vdc. The Main
Control Board suppresses this condition by temporarily
suspending printing. If the condition does not change
the Main Control Board will enable the FAN ALARM
(Alarm 60) Refer to Section 4 of this Service Handbook.
ALM
This signal is sent by the Main Control Board when an of
an overdrive condition is detected in either the printhead
line feed motor or bail/ribbon motor drive circuits. The
power supply disables the + 38 vdc output when this
signal is detected.
Содержание ML393C Plus
Страница 74: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 125: ...Copyright 1997 Okidata Division of OKI America Inc All rights reserved See the OKIDATA Business...
Страница 126: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 278: ...Partner Exchange BPX for any updates to this material http bpx okidata com...