Page: 73
Service Guide ML393/ML393CPlus
Chapter 3 Maintenance
3.2.20 Printhead Gap / Release Lever Microswitches
1. Remove the upper cover assembly
(3.2.04
).
2. Remove the mounting screw to remove the adjust and release lever micro switch (1).
3. Push down on the mounting tab and remove the printhead gap microswitch (2).
4. Using a needle nose pliers, detach the nylon cable clamp (3) and remove the harness and switches
from the printer mechanism.
5. The printhead gap indication bracket is the plastic piece imprinted with numbers. [
Not Shown
]
P/N 56209901 Switch: Micro (Adj and Rel Lever)
RSPL B.2.06
, B.2.09
P/N 53063801 Bracket: PH Gap Indication
RSPL B.2.07
, B.2.09
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business