Page: 149
Service Guide ML393/ML393CPlus
Chapter 4 Failure Analysis
RAP 10D: Data Receive Failure (Alarm Light Lit)
START
Remove the upper cover.
Press and hold the cover open microswitch while powering ON the printer.
Does the alarm lamp come on?
NO Perform the operations listed below.
1. Correctly connect cable CN13 on the control board.
2. Check the alignment between the front access cover and the COVER OPEN switch.
3. Replace the COVER OPEN microswitch/cable assembly.
YES Is the paper properly installed?
NO Install the paper properly.
YES Does the continuous form end microswitch function correctly?
NO Perform the operations listed below.
1. Correctly connect CN103 on the interface connector board.
2. Replace the sheet feeder assembly L.
YES Does the single sheet end sensor function correctly?
NO Perform the operations listed below.
1. Clean the sensor surface.
2. Correctly connect CN1 on the sensor board.
3. Replace the sensor cable assembly.
YES Does the bottom feed paper end sensor function correctly?
NO Perform the operations listed below.
1. Clean the sensor on the sensor board.
2. Correctly connect cable CN4 on the control board.
3. Replace the sensor board.
YES Go to A.
A
Does the release lever microswitch function correctly?
NO Perform the operations listed below.
1. Correctly connect cable CN9 on the main control board.
2. Replace the release lever, microswitch, and cable assembly.
Содержание ML393C Plus
Страница 74: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 125: ...Copyright 1997 Okidata Division of OKI America Inc All rights reserved See the OKIDATA Business...
Страница 126: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 278: ...Partner Exchange BPX for any updates to this material http bpx okidata com...