45641001TH Rev.1
11-82 /
Oki Data CONFIDENTIAL
05/
08
Mode
Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08
Setting
mode
System
Maintenance RDMS
9719
Short time
interval setting of
Emergency Mode
60
30-360
SYS Unit: Minute
1
08
Setting
Mode
System
Maintenance RDMS
General
9723
Periodical polling
timing
1530
0-2359
SYS (Hour/Hour/Minute/Minute)
0 (0:00) to 2359 (23:59)
1
08
Setting
Mode
System
Maintenance RDMS
General
9724
Writing data of self-
diagnostic code
0
0-1
SYS 0: Prohibited
1: Accepted
1
08
Setting
Mode
System
Maintenance RDMS
General
9726
Remote-service
initial registration
0
0-3
SYS 0: OFF
1: Start
2: Only certification is scanned
3: RDMS communication starts
1
08
Setting
Mode
System
Maintenance RDMS
General
9727
Remote-controlled
service tentative
password
-
10 letters SYS Maximum 10 letters
11
08
Setting
Mode
System
Maintenance RDMS
General
9729
Status of remote-
service initial regist
0
0-1
SYS 0: Not registered
1: Registered
2
08
Setting
Mode
System
Maintenance RDMS
Call /Display
function
9730
Service center call
function
1
0-2
SYS 0: OFF
1: Notifies all service calls
2: Notifies all but paper jams
1
08
Setting
Mode
System
Maintenance RDMS
HTTP
9732
Service center call
HTTP server URL
setting
-
-
SYS Maximum 256 letters
11
08
Setting
mode
System
Counter
External counter
9736
Interrupt copying
0
0-1
SYS 0: Invalid
1: Valid
1
08
Setting
Mode
System
Maintenance RDMS
Call /Display
function
9739
Toner-end
notification
0
0-2
SYS 0: RDMS toner empty notified immediately
1: RDMS toner empty notified once a day
2: RDMS toner empty not notified
1
08
Setting
Mode
System
Maintenance RDMS
HTTP
9740
HTTP proxy setting
1
0-1
SYS
0: Valid
1: Invalid
1
08
Setting
Mode
System
Maintenance RDMS
HTTP
9741
HTTP proxy IP
address setting
Refer to
contents
-
SYS Input IP address or FQDN.
<Default value>
0.0.0.0
11
08
Setting
Mode
System
Maintenance RDMS
HTTP
9742
HTTP proxy port
number setting
0
0-65535 SYS
1
08
Setting
Mode
System
Maintenance RDMS
HTTP
9743
HTTP proxy ID
setting
-
-
SYS Maximum 30 letters
11
08
Setting
Mode
System
Maintenance RDMS
HTTP
9744
HTTP proxy
password setting
-
-
SYS Maximum 30 letters
11
08
Setting
Mode
System
Maintenance RDMS
HTTP
9745
HTTP proxy panel
display
1
0-1
SYS
0: Valid
1: Invalid
1
Содержание MB760