45641001TH Rev.1
5-55 /
Oki Data CONFIDENTIAL
[F106_3] aDI-HDD error: aDI authentication admin Password generation error
Classification
Error item
Other service call
ADI-HDD error: The generation of ADI authentication Admin Password
fails.
Check item
Measures
Setting
Reinstall the system firmware.
Reinstall the system software.
[F106_4] aDI-HDD error: authentication random number generation error
Classification
Error item
Other service call
ADI-HDD error: The generation of a random number for authentication
data fails.
Check item
Measures
Setting
Reinstall the system firmware.
Reinstall the system software.
[F106_5] aDI-HDD error: authentication data transmission error
Classification
Error item
Other service call
ADI-HDD error: The transmission of authentication data fails.
Check item
Measures
Setting
Reinstall the system firmware.
Reinstall the system software.
• In case this error occurred after returning SRAM data for SRAM
cloning:
Copy the ADI-HDD encryption key from FROM to SRAM.
1. Start the equipment in the 3C mode: [3] + [C] + [POWER]
2. The authentication menu is displayed. Press [OK]. (Not required in the
default setting)
3. Select “5. Key Backup Restore” and then press the [START] button.
4. Select “6. ADIKey FROM to SRAM” and then press the [START]
button.
5. After the restoring of the encryption key has completed, “Operation
Complete” is displayed.
6. After the operation has completed, shut down the equipment by
pressing the [POWER] button.